Technical Information; Electrical Specifications; Physical Dimensions - Atmor Thermo Boost 10.5 kW Guía De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Information

Electrical Specifications

Heating elements
Watts
Kilowatts
Voltage
Circuit breaker amperage
Breaker/relay
Total connection load
Cable size (minimum)
Plumbing Specifications
Minimum water flow to activate unit 0.5 gpm
Working pressure
Tested pressure
Water connections
Flow Rate
Temperature Rise
Δt (°F)
77
45
35

Physical Dimensions

Height
1
9
/
in.
2
(235 mm)
3
Thermo Boost
10.5 kW
2
10,500 W
10.5 kW
240 V
50 A
double-pole
43.7 A
6 AWG
7–115 psi (0.5–8 bar)
230 psi (16 bar)
1/2" NPT
Thermo Boost
10.5 kW
0.87
1.7
2.2
Width
3
11
/
in.
8
(289 mm)
Thermo Boost
14 kW
14,000 W
double-pole
4 AWG
Flow Rate (gpm)
Thermo Boost
14 kW
Depth
1
4
/
in.
8
(104 mm)
2
14 kW
240 V
70 A
58 A
0.95
2.3
2.9
Weight
5 lb 11oz
(2.58 kg)

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Thermo boost 14 kw

Tabla de contenido