codes).
3 - The LED DL1 will then remain active for 10 seconds enabling possible
cancellation of codes.
4 - Set DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.
C
ONTROL ACCESSORIES OPERATION
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE
CONNECTED.
Make sure that any other type of command accessories (e.g.
mass detectors) used on the installation are set in the IMPULSIVE
mode, otherwise, the gate will be operated even without the
protection of the safety devices.
STEP-BY-STEP BUTTON (COM-K BUTTON)
If DIP6 ON => It cyclically performs the commands open-stop-close-stop-
open etc.
If DIP6 OFF => Opens the gate when closed. There is no effect if activated
while opening. If activated when gate is open, the gate
closes. If activated while closing, the gate reopens.
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary. If
activated while closing, it reopens the gate.
CLOCK FUNCTION OF OPEN BUTTON
If you want the Clock Function must request T2 24V with firmware
02.
ATTENTION: A CLOCK CONNECTED TO T2 24V with fw 03 or more
ACTIVATES THE OPENING MOVEMENT OF THE GATE WITHOUT
HAVING THE PROTECTION OF THE SAFETY DEVICES!
This function is useful during peak hours, when vehicle traffic is slow (e.g.
entry/exit of workers, emergencies in parking or residential areas and,
temporarily, for moving operations).
CLOCK FUNCTION APPLICATION
It is necessary to request a T2 24V control panel with firmware 02.
By connecting a switch and/or a daily/weekly clock (instead of or in parallel
to the open button N.O. "COM-OPEN"), you can open and keep the
automation open for as long as the switch is pressed or the clock remains
active. Command functions are inoperative with open automation.
Releasing the switch or at the preset time, the automation closes
immediately.
CLOSE BUTTON (COM-CLOSE)
Controls the closing movement when the gate is stationary.
REMOTE CONTROL
If DIP6 ON => It cyclically performs the commands open-stop-close-stop-
open etc.
If DIP6 OFF => Opens the gate when closed. There is no effect if activated
while opening. If activated when gate is open, the gate
closes. If activated while closing, the gate reopens.
PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)
Partial opening and closing control.
During pedestrian opening, pausing or closing, you can control the opening
of any command linked to the T2 24V board.
With DIP 6 you can choose the operation mode of the pedestrian push
button.
If DIP6 ON => It cyclically performs the commands open-stop-close-stop-
open etc.
If DIP6 OFF => Opens the gate when closed. There is no effect if activated
while opening. If activated when gate is open, the gate
closes. If activated while closing, the gate reopens.
ELECTRIC LOCK (LOCK)
Set DIP 8 to ON to enable control of the electric lock when opening.
ELECTRIC LOCK PULSE RELEASE IN OPENING
Set DIP 9 to ON to enable the electric lock pulse release when opening
(provided DIP 8 is ON).
If a command to open the gate is given when the gate is closed, the
closing movement is performed for 0.5 seconds and the electric lock is
simultaneously activated (followed by a 0.5 second pause and then the
opening of the gate).
ELECTRIC LOCK PULSE ENGAGEMENT
Set DIP 10 to ON to enable the pulse engagement of the electric lock when
closing. Upon closing, motors are activated for 0.5 seconds at full voltage
to ensure lock engagement.
EASY MOTOR RELEASE
Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is
ON), upon closing a reverse motion with a fixed time of 0.2 seconds occurs
to facilitate manual release.
O
PERATION OF SAFETY ACCESSORIES
PHOTOCELL (COM-PHOT)
DIP 4 OFF => if an obstacle is placed in range of the photocells when the
gate is closed, the gate does not open. During operation,
photocells work when opening (by starting the opening
movement only after the obstacle is removed) and closing
(by starting the reverse movement only after the obstacle is
removed).
DIP 4 ON => if an obstacle is placed in range of the photocells when
the gate is closed and the command to open is given, the
gate opens (the photocells do not work while opening).
Photocells work only during closing (with reverse motion
restored after a second, even if they are still engaged).
CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT
OF PHOTOCELLS
DIP 16 ON and DIP 4 OFF => if photocells are engaged during opening,
DIP 16 ON and DIP 4 ON => if photocells are engaged during opening,
DIP 12 OFF =>
N.B.: Please check photocell operation at least every six months.
EDGE (SAFETY STRIP) (COM-EDGE)
If engaged during opening, reverses the motion when closing.
If engaged when closing, reverses the motion when opening.
If it remains engaged again, it performs a further reversal after 2 seconds,
then performs an additional short reversal and then gives the sensor failure
or engaged alarm (N.O. contact).
If the sensor remains engaged (N.O. contact) no movement is allowed.
If not used, jump the terminals COM-EDGE.
MONITORING OF SAFETY SENSORS (A+ TEST A-)
Sensors can be monitored through the A+ TEST input and DIP 12 ON.
The monitoring consists of a functional test of the sensor run after every
full gate opening.
Closing the gate is therefore permitted only if the sensors have passed the
functional test after each opening.
CAUTION: MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED
WITH DIP 12 ON OR DEACTIVATED WITH DIP 12 OFF. IN FACT, THE
27
27
the gate stops and the gate only closes
one second after the photocells are
disengaged.
the gate continues to open. Upon
disengagement of the photocells, the gate
stops and reverses closing motion after a
one second pause.
If total opening is reached (end of
opening
time),
immediate
is deactivated and automatic time
closing is activated (if TCA trimmer is
activated and LED DL6 is on). If during
closing there is a rapid movement (e.g.
pedestrian) the gate will open again for
two seconds and then close once again.
immediate closing after movement in front
of the photocells is deactivated.
G
B
closing