TO AVOID the flattening of the cable by heavy machinery with could cause breakage.
Do not permit untrained personnel to operate the motor or connexion.
Maintain free ventilation of air.
Keep the converter clean and dry.
Before doing any work of maintenance, disconnect the motor from the electrical system.
When connecting to a generator, make sure that the out tension and frequency is stable, right and
has the proper power.
(the converter feeding voltage should not vary than +/- 5% as stated on the converter plate.
The level of acoustic pressure is less than 70 dB. Proper protective equipment should be used when
the noise level gets to be more than 70 dB.
Respect the maximum number of vibrating pokers that can be connected to the converter.
Avoid having the converter working unloaded during long periods of time. The vibrating pokers
should not be working out of concrete. Switch on the poker before starting working an disconnecting
them immediately after finishing the vibrating operation.
When finishing the job or when taking a break, the operator should switch off, disconnect it from the
electrical system, place it in such a way that should not fall or tip
This screed can be used only under the applications for which it has been designed and according to
these safety instructions.
When working with a petrol engine:
The acoustic power level of this machine can reach 95 dB. Proper protective equipment should be
used.
en
IN ADDITION, LOCAL COUNTRY STABLISHED ORDINANCES SHOULD BE RESPECTED.
4
OPERATION AND MAINTENANCE
4.1 GETTING STARTED
1.- Before starting the job, check the correct working of all handling and safety devices
2.- Inspect regularly the good conditions of the feeding cables. If is necessary change the cord,
check section Extension cables.
3.- Inspect regularly the connection voltage.
4.- The converter should only be used in conjunction with all safety elements.
5.- Check the screws
6.- If defects are found in the safety devices or other defects which could reduce the safe handling of
the equipment, notify immediately the proper responsible person.
4.2 VIBRATING POKER CONNECTION TO THE CONVERTERS
The converter has a socket to connect the vibrating pokers.
Connection possibilities:
The input current of the pokers connected in load shall not exceed the out current specified in the
electrical characteristic table.
8
AFG, AFD, AFE
- Read the motor manufacturer's manual before working.
- Do not work in closed rooms, the exhaust fumes may be toxic.
-·Wait 2 minutes for the petrol refill until the motor get colder.
FRECUENCY CONVERTERS