Connecting Cable; Description; General Characteristics; Operation - ICAR 5LSA Instrucciones De Uso

Ocultar thumbs Ver también para 5LSA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.1 DESCRIPTION

The cable includes a RS232/TTL converter, which allows converting the TTL signals, in-
coming and outgoing via the rear connector of the controllers, into an isolated RS232 sig-
nal, connectable to a PC. It is designed so that the set-up and the customising of func-
tions of such devices can be achieved, via the appropriate software, on controllers pro-
vided with relative communication port connector.

3.2 GENERAL CHARACTERISTICS

RS232/TTL isolated interface
Interface supply derived from the controller
Connection to PC by SUB-D 9-pin female connector.

3.3 OPERATION

Connect the RJ6/6 phone jack to the controller and the SUB-D 9-pole connector to the PC
serial port.
By installing and opening the programming software, check if the connection is working
correctly.

3.4 TECHNICAL CHARACTERISTICS

Maximum communication speed
Insulation between RS232/TTl
Operating temperature
Storage temperature
Degree of protection
Connector to PC
Connector to controller
Total cable length
Converter dimensions WxHxD
Reference standards

3. CONNECTING CABLE

50
19200 baud
2.5kVAC for 1min
-10... +50° C
-30... +80° C
IP00
9-pin SUB-D female
RJ 6/6
<3m
18x18x70mm
IEC/EN 60950 (2001)
EN 55022 (1998)+A1
EN 61000-4-3 (1995)+A1
EN 61000-4-2(1998)+A1/A2
EN 61000-4-6 (1996)+A1
EN 61000-4-4 (1995)+A1
EN 61000-4-8 (1994)+A1
EN 61000-4-5 (1995)+A1