6 Generator usage:

WARNING: To make sure the generator to ground the generator
(grounding rod). If you have questions, check with your electrician.
WARNING: Never connect the 230 voltage output of the equipment to a
building or house (not even during a power outage). The return of the main
network would clash with the generator's voltage and cause serious damage to
the equipment or even a fire.
WARNING: Do not connect in parallel with the generators, both will be
damaged and will be a fire hazard.
NOTE: Do not connect an extension to the exhaust.
NOTE: If a cable extension is needed, make sure you use a good quality
rubber extension (as per IEC245 or equivalent standards) and appropriate
section:
 60m cable length: use 1.5mm
 100m cable length use a 2.5mm
NOTE: Devices that use an engine such as compressors, water pumps,
saws, radials, etc. require up to 3 times more power for startup. For example, a
500 W water pump would need a 1500 W generator for startup. Verify that
charges upon connection do not exceed the maximum power of the group
according to this guideline.
GROUNDING
GROUNDING SYMBOL
2
cable;
2
cable
14