Display

After quickly pressing the ON/OFF button (11) on the display (9), the charge level will be visible for about 5 seconds with
the following modes:
4 led bars – 80/100% charge level
3 led bars – 60/80% charge level
2 led bars – 40/60% charge level
1 led bar – 20/40% charge level
1 flashing led light – charge level is lower than 20%
All flashing LED lights with repetition each second = Error status.
If any undervoltage is detected, it persists even if the battery is switched off and then on again, until it reaches at least the
20% of its status of charge (SoC).
WARNING!
If the problem cannot be solved, take the battery to an Authorized Service Point.
5.2.1

ON/OFF battery led light

When the button is pressed while switching off the battery, the timed lit-up led bars quantity will decrease up to zero.
When the last LED bar is off, the battery switches off by releasing the button.
5.2.2

ON/OFF power supply management

When the battery is off, it is switched on by pressing the button. The charge level can be seen for 5 seconds.
When the battery is off, it is switched on by connecting it to the charger. The charge level can be seen on as long as
the charger is connected.
If the consumption is less than 200 mA, the self-switching-OFF timer is activated. Timing depends on the battery pack
status of charge (SoC).
The operator can switch off the battery by keeping the button pressed for at least 5 seconds.
The battery switches off automatically, when the charger is disconnected or when charge is complete
While the battery is charging, it cannot be switched off.
5.3

Battery re-charging

For the recharge operations please read the manual of the battery-charger.
5.4

Troubleshooting

WARNING!
All the following maintenance operations shall be carried out by a mechanical maintenance technician.
FAULT
The battery does not turn on
The battery is off
The battery display is flashing Error detected
Use and maintenance manual – Translation of
original Instruction Rev.: 00, Date 16/07/2019
CAUSE
Flat battery
Auto switch-OFF entered
RIMEDY
Re-charge the battery
Turn the battery ON (4) by means of the switch.
Switch the battery off and on again to reset the error.