5. Operating Location

If you ...
-
wish to mix in odorisation agents or
-
use solenoid valves,
please always fit them only downstream of the meter. Otherwise, the device may be
damaged.
The flow through the meter must be free of vibrations / pulsations in order to avoid
measuring errors.
Compliance with the specified operating and ambient conditions as indicated on
the type label is absolutely essential for safe operation of the meter and additional
equipment.
The gas may not contain suspended particles > 50 µm. In addition, the gas must
be dry. Otherwise, the meter may be damaged.
To protect the meter, a cone strainer with mesh size 250 µm must be installed on all
new installations, and is also recommended for existing installations. When installing
the meter in a vertical position, with the direction of flow from bottom to top, a strainer
must be fitted to both the meter inlet and outlet (to protect against falling dirt).