Maintenance - Clarke Super 7R Edger Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE

CAUTION:
Maintenance and repairs performed by
unauthorized personnel could result in damage or injury. Maintenance
and repairs performed by unauthorized personnel will void your
warranty. Failure to perform maintenance at recommended intervals
may void warranty.
Carbon Brushes
Inspect all four brushes every 6 months or 250 hours. Access to the
brushes is gained through the front and back motor vent plugs and un-
der both motor covers (fi gure 7). Press tab (A) on spring clip assembly
in, rotate, then remove (fi gure 8).Use needlenose pliers to disconnect
the shunt wire. If any brush has worn to 3/8" in length or shorter,
replace the entire set.
CAUTION:
Use only motor brush PN 40818A or PN
40055A with shunt wire or motor failure will occur.
When replacing the brushes make sure that the brush seats against the
commutator, the spring rest in the recess of the brush, and the brush is
free to travel. When returning the switch cover, keep any wires clear of
the commutator and any pinch site.
To Change The Lubricant In The Gearbox
To change the lubricant in the gearbox, follow this procedure:
1. Put the machine upside down on a bench.
2. Align one of the two holes in the rubber pad with one of the three
holes in the rotating wall guard.
3. Align both holes with one of the three screws in the gear housing
cover. Remove the screw from the gear housing cover. (Figure 9)
4. Align the holes with each of the other two screws, then remove
screws.
CAUTION:
Make sure no dust enters the gear box.
Damage will occur to the gear box.
5. Remove the cover from the gear housing.
6. Remove the old lubricant from the gearbox.
7. Add six ounces of American SandersTechnology lubricant to the
gear box.
CAUTION:
To prevent damage to the motor, do not add
more than six ounces of lubricant to the gearbox.
8. Using the three screws removed above, install the cover on the
gear housing.
9. Start the machine and let it run for 15 minutes. A small amount of
excess lubricant should fl ow out the vent hole. If none appears it
may be necessary to add additional lubricant.
10. Wipe off excess lubricant and clear vent hole.
American Sanders Operator's Manual (EN) - Super 7R
Clarke
®
ENGLISH
Figure 7
A
Figure 8
Lubricants
Qty
Part No.
1Qt.
16610A
1Gal.
16611A
Figure 9
FORM NO 70402B - 11 -
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

07013a07125a07098a

Tabla de contenido