Common Point
Supply
Connection for
position indication
Changing over time
Wiring diagram:
S1 ...
contact switch 1
S2 ...
contact switch 2
S3 ... contact switch 3
S4 ... contact switch 4
M
...
motor
ST ...
disc cam
U ... electricity supply
18.

Troubleshooting:

The ball valve does not move freely
o The thrust collar was over-tightened
The ball valve is preset and the thrust collars must not be modified
Reset the thrust collar to the original position
o The union nut was over-tightened
Loosen the union nut and tighten manually
o The compensating thrust collar on the solar ball valve is in the wrong position
See item 12.1 Comments to the 3-way Solar ball valve:
o Temperatures in the system too high