Troubleshooting:
The ball valve does not move freely
o The thrust collar was over-tightened
The ball valve is preset and the thrust collars must not be modified
Reset the thrust collar to the original position
o The union nut was over-tightened
Loosen the union nut and tighten manually
o The compensating thrust collar on the solar ball valve is in the wrong position
See item 12.1 Comments to the 3-way Solar ball valve:
o Temperatures in the system too high
Use the right ball valve material for the temperatures in question
Please ask our service engineers
o The medium does not match the material
Use the right ball valve material for the medium in question
Please ask our service engineers
The drive is no longer rotating
o No voltage
Check the voltage at the terminals
Check the electrical installation
o Incorrect voltage at the terminals
Check the voltage at the terminals
Provide voltage to the terminals as specified on the type plate.
o Extended period of disuse
Rotate the ball valve manually
o The compensating thrust collar on the solar ball valve is in the wrong position
See item 12.1 Comments to the 3-way Solar ball valve:
o Foreign matter in the system
Remove the foreign matter
Integrate a filter into the system
o Damage to the ball and seal
Replace the ball and seals
Integrate a filter into the system
The ball valve is leaking
o You are using a Solar ball valve
The Solar ball valve does not provide a hermetic seal
See item 12.1 Comments to the 3-way Solar ball valve:
o Foreign matter in the system
Remove the foreign matter
Integrate a filter into the system
o Damage to the ball and seal
Replace the ball and seals
Integrate a filter into the system
o The ball valve does not move freely
See item 1 in Troubleshooting