en - English
How it works
The XCI box allows external hardware
from Miele and other suppliers to be
connected to the Miele Professional
machine. External hardware includes
payment systems, dispensing systems,
peak load systems, pressure sensors
and external exhaust valves.
These operating and installation instruc-
tions primarily describe how to connect
payment systems. Connections for ex-
ternal hardware other than payment
systems must be made by an author-
ised Miele Service engineer.
Installation
Servicing, modification, testing and
maintenance of electrical appliances
must be carried out in accordance with
all appropriate legal requirements, acci-
dent prevention regulations and valid
standards.
All regulations of the appropriate utility
supply companies and standards relat-
ing to electrical and general safety must
be observed.
Danger of injury due to electric
shock.
Even with the machine switched off,
mains voltage may be applied to
some components.
The Miele Professional machine must
be disconnected from the mains be-
fore performing any maintenance or
repair work.
A machine safety check must be car-
ried out in accordance with national
regulations (e.g. VDE 0701 in Germany).
34
The XCI box must be accessible at all
times to enable service work to be car-
ried out.
Read and observe sections "Current
carrying capacity of the inputs and out-
puts" and "Installing a payment system"
before connecting the additional com-
ponents to the XCI box.
Before securing the XCI box
- The XCI box must be screwed into
place properly on site. The dimen-
sions of the holes to be drilled into
the wall are quoted in Fig. in the
"" chapter at the end of these op-
erating and installation instructions.
- Alternatively, the XCI box can be at-
tached to the wall using the adhesive
strips provided. If you choose this
option, please note:
– The adhesive strips are attached
along the outer edges and in the
centre of the rear panel. See
Fig. in the "" chapter at the
end of these operating and install-
ation instructions.
– The surface of the wall must be
smooth and solid with no traces of
grease or dust.
– It must not be covered with tex-
tured wallpaper, textured plaster or
any other surface finish with inad-
equate adhesion properties.
– The maximum mounting height
must not exceed 1.50 m (59").
Do not install the XCI box above un-
covered water holes, gutters or sim-
ilar systems.