Output Edit Menu - Ecler ALMA26 Manual De Instrucciones

Ocultar thumbs Ver también para ALMA26:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. OUTPUT EDIT MENU

To open the edit menu for the settings of an output, you have to press SHIFT + MUTEx, MUTEx
being the output 1 to 6 MUTE key.
Once in the edit menu for an output, and in one of its pages, it is possible to obtain the same
page for another output by pressing SHIFT + MUTEx, MUTEx being the MUTE key for the other output.
The new edited values are activated in real time. You can cancel an edit operation, bringing back
the value before editing, by pressing SHIFT + CANCEL.
To exit the Edit menu and return to the main screen:
Press SHIFT + EXIT
Press SHIFT + MUTEx (the MUTE key of the output x currently edited)
Stay 2 minutes without operating any control on the front panel
The next page shows the full structure and options of the menu for setting outputs.
NOTES:
1. In the setting pages of the 8 parametric filters available for each output, the displayed
abbreviations meaning is:
BYP: BYPASS (filter not activated)
PEQ: PARAMETRIC EQ
HS6 / HS12: HIGH SHELF 6 or 12 dB/octave
LS6 / LS12: LOW SHELF 6 or 12 dB/octave
HP6 / HP12: HIGH PASS 6 or 12 dB/octave
LP6 / LP12: LOW PASS 6 or 12 dB/octave
AP1 / AP2: ALL PASS 1st or 2nd order
2. In the setting pages of the Hi-Pass and Low-Pass crossover filters available for each output,
the displayed abbreviations meaning is:
BYP: BYPASS (filter not activated)
BES12, 18, 24, 48: BESSEL-type filter, 12, 18, 24 or 48 dB/octave
BUT6, 12, 18, 24, 48: BUTTERWORTH -type filter, 6, 12, 18, 24 or 48 dB/octave
LR12, 24, 48: LINKWITZ-RILEY-type filter, 12, 24 or 48 dB/octave
3. The COPY FROM – PASTE TO operation copies all the settings from the source output to the
destination output, except for its source selection (SOURCES) and its name (LABEL)
14

Publicidad

Tabla de contenido
loading

Tabla de contenido