Connect the MFM 1-4-5 coding plug to plug ST3 on the module. See Fig. 2.
A
Connect screw-terminal strip to plug ST12 on the module. See Fig. 2.
The power (L, N) and control (bus) wiring harnesses must be laid separately in order to avoid interference in the
control circuit (electromagnetic compatibility).
Excess cable should be gathered so that current flows in opposite directions and tied to avoid any antenna effect.
A
Lay and connect the "N1-16_X3-4" wiring harness. See Fig. 2.
A
Lay and connect the "N1-1, N1-16 L, N" wiring harness; see Fig. 2.
A
Lay and connect the "N1-1, N1-16 bus" wiring harness; see Fig. 2.
A
Connect the flow meter connections in accordance with the wiring diagram.
A
Reinstall the machine lid.
A
Log the module on; see the "service mode" section in the model-specific TSD.
A
Activate the flow meter monitor. See the "service mode" section in the model-specific TSD.
Installing flow meter module 7 as the second or third module
A
Remove the machine lid; see the model-specific TSD.
A
Install the module mounting bracket (3) with fixing brackets (4) onto the crossbar, or onto other existing mounting
brackets. See Fig. 3.
A
Secure the module (1) with spacers (2) onto the mounting bracket (3). See Fig. 3.
A
Install the terminal strip (5) in the pre-punched holes on the crossbar. See Fig. 3.
A
Connect the MFM 1-4-5 coding plug to plug ST3 on the module. See Fig. 4 or 5.
A
Connect the screw-terminal strip to plug ST12 on the module. See Fig. 4 or5.
The power (L, N) and control (bus) wiring harnesses must be laid separately in order to avoid interference in the
control circuit (electromagnetic compatibility).
Excess cable should be gathered so that current flows in opposite directions and tied to avoid any antenna effect.
A
Lay and connect the "1N1-1, 2N1-16 L, N" wiring harness. See Fig. 4 or 5.
A
Lay and connect the "1N1-1, 2N1-16 bus" wiring harness. See Fig. 4 or 5.
A
Connect newly added terminal strips to existing terminal strips where present using the supplied brown wire. See
Fig. 4 or 5.
A
Connect the flow meter connections in accordance with the wiring diagram.
A
Reinstall the machine lid.
A
Log the module on; see the "service mode" section in the model-specific TSD.
A
Activate the flow meter monitor. See the "service mode" section in the model-specific TSD.
en-US
el
Οδηγίες τοποθέτησης μονάδας 7 για μετρητή ποσότητας νερού
Αιτία: Η μονάδα χρειάζεται για να συνδεθούν οι μετρητές ποσότητας νερού στο πλυντήριο ρούχων.
Περιεχόμενα μέρη
Αριθμός Κωδικός
Ονομασία
προϊόντος
1
Ηλεκτρονικό EZL 235, μονάδα 7
16.03.2018
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
M.-Nr. 10717801

Publicidad

loading