Descargar Imprimir esta página

Miele C4060 Instrucciones De Montaje página 17

Sistemas de cobro

Publicidad

M.-Nr. 05719362
A
Place rubber mat supplied on the machine lid and align it with the edges of the machine lid with W = 35 mm and Z =
80 mm.
This serves as the drilling template, see Fig. 1.
A
Drill 6.5 mm diameter holes, see Fig. 1.
A
Open the front panel of the payment system.
A
Fix rubber mat (1) over the pre-drilled holes, see Fig. 2.
A
Secure payment system to machine lid using fixing materials supplied.
A
Push out the pre-punched feed-through hole in the back panel.
A
Connect cable (3) to the 7-pole plug in the machine, see Fig. 2.
A
Attach cable strain relief (2), see Fig. 2.
An adapter (8) may be required for payment systems C4065 and C4070, see Fig. 2. For more information see
information sheet "Connection information for C4065/C4070" payment systems supplied. The adapter must then be
secured to the wiring harness with cable ties.
A
For C4065 and C4070 disconnect bridges (6) on plug (5) in the machine in accordance with the information sheet,
see Fig. 2.
A
For C4060 disconnect bridges (6) on plug (5) on machine in accordance with the wiring diagram, see Fig. 2.
T5200, T5250
For safety reasons the connection cable must not exceed 2.5 m in length.
A
Place rubber mat supplied on the machine lid and align it with the edges of the machine lid with x = 60.5 mm and Y
= 31 mm.
This serves as the drilling template, see Fig. 3.
A
Drill 6.5 mm diameter holes, see Fig. 3.
A
Drill a 3 mm diameter hole, see Fig. 3.
A
Drill a 30 mm diameter hole, see Fig. 3.
A
Open the front panel of the payment system.
A
Fix rubber mat over the pre-drilled holes.
A
Secure payment system to machine lid using fixing materials supplied.
A
Bridge sequential circuit contacts P3. P5 and P7.
A
Plug contact 9 to 13 and contact 17 to 21.
A
Withdraw contacts 25 and 31 and bridge with plug connections.
A
Remove sequential circuit surge (9), see Fig. 4.
A
Cover the drill holes in the switch panel with stickers Mat. No. 90179.
A
Draw the connection cable through strain relief (10), see Fig. 4.
A
Connect cable to the 7-pole plug in the machine.
An adapter may be required for payment systems C4065 and C4070. For more information see information sheet
"Connection information for C4065/C4070" payment systems supplied. The adapter must then be secured to the
wiring harness with cable ties.
A
For C4065 and C4070 disconnect bridges on plug in the machine in accordance with the information sheet.
T6200, T6250, T6251
For safety reasons the connection cable must not exceed 2.5 m in length.
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
17 von 56
21.12.2017

Publicidad

loading

Este manual también es adecuado para:

C4065C4070