English
Ventilation
Your heater consumes oxygen while it is in operation. For that reason,
adequate ventilation should be provided in rooms in which the heater is used.
This ensures the removal of products of combustion and allows the entry of
replacement air.
Adequate
ventilation
condensation occurring. The following table shows the smallest sizes of room
suitable for each heat setting and the ventilation surface, which should be
provided.
Required volume of room and ventilation surface:
VOLUME OF LIVING ROOM
84 m
Assembling the heater and connecting the gas cylinder
1. After removing the heater from its packaging, check it for damage: if you
are unsure, do not use the appliance and contact qualified service
personnel. The packing materials should not be left within the reach of
children because they are potentially dangerous; dispose of them in
conformity with the law.
2. Remove from the cabinet the cover on the gas cylinder, and unscrew.
3. This device must only be powered with LPG gas in a 15-kg cylinder and this
must be equipped with a pressure regulator and flexible tube. The pressure
regulator must have a fixed calibration of 30 mbar conforming to EN12864
and the flexible rubber tube, with a length of 50 cm (and not longer than
60 cm); the latter must be attached with metal bands of suitable size and
needs to be replaced by the date stamped on it.
4. The flexible hose must be an approved hose (BS3212 type 2 or BSEN1763
Class B) checked regularly whenever the cylinder is replaced to be sure it
has no scratches or cuts and it is in a perfect state. We recommend
replacing the gas hose every 3 years.
5. Connect the flexible tube to the hose union of the pressure regulator and
to that of the tap, checking that the metal bands are tight and paying
particular attention not to tamper with or damage any component or
fitting.
6. Before connecting the cylinder, make sure that its tap is closed and that
there are no open flames (lit oven, etc.) in the room, where the stove is
4
should
considerably
3
reduce
VENTILATION SURFACE
Low Level
105cm
2
Instructions for use
the
possibility
High Level
105 cm
2
of