Advanced troubleshooting for service
AUTOMATIC ELECTRONIC DIAGNOSTICS
This water softener has
a self-diagnostic function
for the electrical system
(except into power and/or
water meter). The water
softener monitors electronic
components and circuits
for correct operation. If a
malfunction occurs, an error
code appears in the display.
While an error code appears in the display, all buttons
are inoperable except the MODE/SET button. MODE/
SET remains operational so the service person can
perform the Manual Advanced Diagnostics, see below,
to further isolate the problem.
Procedure for removing error code from
display:
1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 8 minutes. The error code will return if the
problem was not corrected.
MANUAL INITIATED ELECTRONIC
DIAGNOSTICS
Use the following procedures to advance the water
softener through the regeneration cycles to check
operation.
Lift off the Salt Hole Cover, remove the top cover by
unlocking the tabs in the back and rocking forward,
to observe cam and switch operation during valve
rotation.
1. Press and hold MODE/SET for 3 seconds until the
Set low salt alarm display appears, next press the
MODE/SET button five addition times until "000"
shows in the display, then release, (see Figure 19).
2. The 3 digits indicated water meter operation as
follows: If you don't get a reading on the display,
with faucet open, pull the sensor from the valve
outlet port. Pass a small magnet back and forth
in front of the
sensor. You
should get a
reading in the
display. If you
get a reading,
Position
shut off water
supply, unhook
the in and
out plumbing
Valve
and check
the turbine for
binding
Call for Service
Figure 18
Motor
shaft
30
3. Symbols in the display indicate POSITION switch
operation, (see Figure 19).
Switch is open
Water Meter
4. Use RECHARGE button to manually advance
the valve into each cycle and check correct switch
operation. NOTE: Be sure water is in contact
with salt, and not separated by a salt bridge (see
Breaking a Salt Bridge section).
5. While in this diagnostic screen, the following
information is available and may be beneficial for
various reasons. This information is retained by
the computer from the first time electrical power is
applied to the electronic controller.
a. Press the
UP button to display the
number of days this electronic control has had
electrical power applied.
b. Press the
DOWN button to display the
number of regenerations initiated by the
electronic control since the code number was
entered.
6. Press and hold the MODE/SET button until the
mode code (H31 for the GXMH31H) shows in
the display (see Figure 20). This code identifies
the softener mode. If an incorrect model code is
displayed, the softener will operate on incorrect
configurations data.
7. To change the code number, press the
DOWN button until the correct code shows.
8. To return to the present time display, press the
MODE/SET button.
9. Press the MODE/SET button to return to the
present time display. If the code was changed,
make all the timer setting. NOTE: If the control
is left in a diagnostic display or a flashing display
when setting times or hardness, present time
automatically returns if a button is not pressed
within four minutes.
Switch is closed
Figure 19
Figure 20
UP or