Pahlen Jet Swim 1200 Manual De Usario página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Jet Swim 1200
Installation - Liner pool
1. Remove the stainless steel front and cut out the pool wall according to the hole pattern. The centre of the Jet Swim housing
shall rest 230 mm under the surface of the water.
2. Install the Jet Swim housing in the wall of the pool. Then attach the self-adhesive gasket on the bronze part.
3. Put the pool liner in place. Fill the pool with water. When the water reaches about 5 cm below the Jet Swim housing,
the clamping ring and rubber washer are screwed in place against it.
Cut away the pool liner from the inside of the clamping ring and install the stainless steel front plate.
4. Connect the hose for the air injecion and tighten the hose clamp. Then attach the end of the hose 100 mm above the surface
of the water behind the pool wall.
5. Attach the starting hose to the pump's contactor cabinet (control box).
N.B.! The starting hose must be fixed in a loop 150–200 mm above the surface of the water.
6. Connect the pipes and valves to the pump according to the image (page 6). The threads are sealed with thread seal tape.
7. The electrical connection must be made by an authorised electrician and be equipped with a residual current device.
8. Make sure that the pump's direction of rotations is consistent with that of the system. Open the valves. Completely fill the
pump with water before starting it with the push-button (A fig.1) on the stainless steel front.
9. The front can be turned one step to the right or to the left to control the water flow and to have air mixed into the water jets,
see fig. 1.
Installation - Concrete pool
1. Remove the stainless steel front and install the Jet Swim housing in the form. The finished pool wall shall be in line with the
flange on the bronze housing. The centre of the Jet Swim housing shall be located 230 mm under the surface of the water.
2. Attach the start hose to the Jet Swim housing and install the non leak flanges for the suction and pressure connections
and the non leak flanges for the air injection and start hose (protective hose) before casting. The threads are to be sealed
with thread tape.
3. Install the stainless steel front plate after the casting (and any tiling).
4. Connect the hose for the air admixture and tighten the hose clamp. Fasten the end of the hose 100 mm above the surface
of the water behind the pool wall.
5. Connect the starting hose to the pump's contactor cabinet (control box).
N.B.! The starting hose must be set in a loop 150–200 mm above the surface of the water.
6. Connect the pipes and valves to the pump according to the image (page 6). The threads are sealed with thread seal tape.
7. The electrical connection must be made by an authorised electrician and be equipped with a residual current device.
8. Make sure that the pump's direction of rotation is consistent with that of the system. Open the valves. Completely fill the
pump with water before starting it with the push-button (A fig.1) on the stainless steel front.
9. The front can be turned one step to the right or to the left to control the water flow and to have air mixed into the water jets,
see fig. 1.
Installation - Concrete pool with liner
Install according to point 1 - 2 for concrete pools and point 3 - 9 for liner pools.
Start
The pump must be filled with water prior to starting. Never run the pump dry,
as that can damage the parts inside. Make sure that all the valves to and from the
pump are open prior to starting.
The Jet Swim pump is started and stopped by air impulse via the pushbutton (A)
on the stainless steel front (see fig.1).
To control the water flow and to have air mixed into the water jets: turn the front
one step to the right or to the left (see fig. 1) :
B = low jet pressure
C = high jet pressure
D = high jet pressure with air added.
Please note
Upon risk of freezing: close the valves, remove and drain the pump of all water.
Lower the water level to approximately 10 cm under the Jet Swim housing in
order to avoid freezing damage.
The pump should be store indoors during the winter.
When restarting: Check the condition of the starting button and the hoses.
B
Low
A
On/Off
8
ENGLISH
Jet Swim 1200 ( Front panel )
C
High
Figure 1.
Front Jet Swim 1200
D
High + Air

Publicidad

Tabla de contenido
loading

Tabla de contenido