Polar CK640 Manual De Instrucciones página 13

Ocultar thumbs Ver también para CK640:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
During storage:
To interrupt the
cycle:
Test To Check Correct Pin Probe Insertion
Set-temperature cycles are preceded by a test step in order to check correct
pin probe insertion.
If power is interrupted during the test, when power is restored, the test will
start again from the beginning.
The test has two stages:
if the outcome of the first stage is positive, the second will not be run
if the outcome of the first stage is negative, the second will be run.
The outcome of the first stage is positive if "the temperature measured by the pin probe - the
temperature of the cabinet" is greater than the value set by parameter rc at least 3 times out of 5 (the
comparison is made every 10 s); if parameter rc is set to 0, neither the first nor second stages will be
run.
The outcome of the second stage is positive if the difference "temperature measured by the pin probe
- temperature of the cabinet" is greater by at least 1ºC/1ºF (with respect to the previous comparison)
at least 6 times out of 8 (the comparison is made every "rd/8 s")
If the outcome of the test is positive:
the cycle will be activated
the cycle will be started in timed mode
the LED
will flash
Setting The Configuration Parameters
The parameters are arranged on two levels.
To access the first
level:
To access the
second level:
CK640_ML_A5_v4_20200728.indb 13
CK640_ML_A5_v4_20200728.indb 13
the display shows the cabinet temperature
if chilling had a positive outcome, the LEDs
chilling had a negative outcome, the LEDs
LED
will flash.
the parameter rA sets the operational set point
press
several times to:
- display the message "nEg"
- exit the procedure, or leave for 15 seconds
press
for 2 seconds
ensure the device is in "stand-by" mode and no procedures are running
press
and
for 4 s: the display will show "PA"
access the first level
press
or
to select "PA"
press
press
or
within 15 s to set "-19"
press
or leave for 15 s
press
and
for 4 s: the display will show "CA1"
UK
and
will be on; if
and
will be on and the
13
2020/7/28 17:38
2020/7/28 17:38