AIRINTAKE FILTER
The filter ( J)isdesigned toclean a irentering
thepump. To
ensure the pump continually
receives a clean, cool, and dry air supply the
filter must always be clean and the filter intake
must be free from obstructions.
INSTALLATION
Assembly
(Fig.
1)
INSTALLING HOSES
_k WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSi (0 kPa).
2. Grasp the hose at the quick connect plug and push the plug
into the quick connect body (E). Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING
HOSES
,_ WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
2. Push coupler on quick connect body back to release quick
connect plug on hose.
Groundin9
Instructions
_WARNING:
Risk of electrical
shock. In the event of a short
circuit, grounding reduces the risk of shock by providing an escape
wire for the electric current. This air compressor must be properly
grounded.
The portable air compressor
is equipped with a cord having a
grounding wire with an appropriate grounding plug.
lO
1. The cord set and plug (R) with this unit
R
contains a grounding pin (S). This plug
MUST be used with a grounded outlet
(T).
IMPORTANT: The outlet being used must
be installed and grounded in accordance
with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as the
grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there
are signs of damage.
4. If these grounding instructions are not completely understood, or
if in doubt as to whether the compressor is properly grounded,
have the installation checked by a qualified electrician.
DANGER:
Risk of electrical shock. IMPROPER
GROUNDING
CAN RESULT IN ELECTRICAL
SHOCK.
• Do not modify the plug provided, ff it does not fit the available
outlet, a correct outlet should be installed by a qualified electri-
cian.
• Repairs to the cord set or plug MUST be made by a quafified
electrician.
Extension
Cords
If an extension cord must be used, be sure it is:
• a 3-wire extension cord that has a 3-blade grounding plug, and
a 3-slot receptacle that will accept the plug on the product
• in good condition
• plug is not worn
• no longer than 50 feet (15,2 m)
• 12 gauge (AWG) or larger. (Wire size increases as gauge num-
ber decreases. 10 AWG and 8 AWG may also be used. DO NOT
USE 14 OR 16 AWG.)