Troubleshooting

-
Problems in the Needle:
SYMPTOM
Needle motor doesn't work.
The needle makes more noise
than normally.
The needle stops when it is
vibrating the concrete.
Doesn't start with below
temperatures.
The needle revolves with a slow
speed and warm it.
General differential fails.
General magnetotermic fails.
ENGLISH
PROBABLE CAUSE
-Loose electric connections.
-Faulty switch.
-Faulty power supply.
-Lack of tension.
-Faulty bearing.
-The thermal protection switch off.
-The grease is solidified.
-Blocked bearings.
-The motor rotor frictioned.
-Current escapes to ground.
-Shortcircuit
OPERATION
COUNTERMEASURE
-Checking and replace if it necessary.
-Replace.
-Rearm.
-Checking the electronic equipment.
-Replace them with original spare.
-Checking electrical parts and bearings.
-Starting the vibrating needles to work
without load enough time until it works
normally.
-Replace bearings with original spare.
-Sending to our factory or Official Agent.
-Check state electric cables.
-Check, if motor burnt.
-Check the status of varistor haused
inside the plug
-Check the status of the power cord and
plug