1.14 Wiring Schematic - Technoflex GOLD Manual De Instrucciones/Lista De Recambios

Vibrador electrónico de alta frecuencia
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1B
OPERATION
-
Problems in the Electronic Equipment
The electronic equipment disposes of three LEDS of which indicates circuit estate or any malfunction.
When functioning normally, the POWER SUPPLY green LED should be on permanently, DON'T
MANIPULATE DE ELECTRONIC PLATE with the green LED on.
The yellow Led indicate the machine is in stop or wait instructions, the red LED indicates malfunction,
OVERCURRENT or OVERLOAD, the type of failures it indicates the number of sparkles in the red
LED, next we show the diferents failures of function :
red LED
Nº Sparkles
1
2
3
4
5
6
Fixed
SYMPTOM
Motor doesn't work.
Overcurrent LED on.
Overload LED on.
Malfunction motor LED on.
Detection lost current to
ground LED on.

1.14 Wiring Schematic

1B-10
Explanation
Less Input tension
Circuit Overheat checked
Input tension so high
Phase failure in the motor
The circuit has checked lost current to ground
Overload in the motor
Overcurrent ( Phase short-circuit )
PROBABLE CAUSE
-Lack of outdoor tension.
-Motor short circuit.
-Blocked bearings or motor working
in two phases.
Phase malfunction in the motor
Current derived to ground
COUNTERMEASURE
-Check outdoor tension.
-Check wires or replace motor.
-Check bearings or check electrical
conductors.
-Check electric wires or replace motor.
- Check electric wires at motor to circuit
ENGLISH