tau D770M Manual De Uso página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
LED: DL7
(green) + DL8
1 flash every 4 seconds (green):
Apart from the logic mistakes, the DL7 LED indicates also the status of the control unit during the sav-
ing of the radio controls.
Always on (green):
Fast flashing (green):
Flashing (green):
Led off:
LED: DL8
(red) + DL7
Led off:
1 flash (red):
7 flashes (red):
8 flashes (red):
Apart from the logic mistakes, the DL8 LED indicates also the status of the control unit during the sav-
ing of the radio controls.
Always on (red):
Fast flashing (red):
Flashing (Rosso):
Led off:
10. MALFUNCTIONS: POSSIBLE CAUSES AND SOLUTION
The automation does not start
a- Check there is 230Vac power supply with the multimeter;
b- Check that the NC contacts of the card are actually normally closed (4 green LEDs on: DL3, DL4, DL5, DL6);
c- Set dip 6 (phototest) to OFF;
d- Check that the fuses are intact with the multimeter.
The radio control has very little range
a- Check that the ground and the aerial signal connections have not been inverted;
b- Do not make joints to increase the length of the aerial wire;
c- Do not install the aerial in a low position or behind walls or pillars;
d- Check the state of the radio control batteries.
The gate opens the wrong way
Invert the motor connections on the terminal block (terminals 4 and 6 for motor 1; terminals 7 and
9 for motor 2);
11. GUARANTEE: GENERAL CONDITIONS
TAU guarantees this product for a period of 24 months from the date of purchase (as proved by the sales
document, receipt or invoice).
This guarantee covers the repair or replacement at TAU's expense (ex-works TAU: packing and transport at
(red led always off)
Normal operation;
Channel CH1 waiting to be saved;
CH1 channel memory full;
CH1 channel waiting to be cancelled;
Cancelling of channel CH1 in progress;
(green led always off)
Normal operation;
Phototest error
Disable phototest (dip-switch 6 OFF), check the operation of the
photocells and their connection;
Sensitive edge safety intervention
A command pulse is required to carry out the closure;
Eeprom external memory fault;
Replace the external memory module;
Channel CH2 waiting to be saved;
CH2 channel memory full;
CH2 channel waiting to be cancelled;
cancelling of channel CH2 in progress;