Safety Instructions; Technical Data - brennenstuhl Premium City SH 8005 IP44 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Installation and Operating Instructions
D
Premium LED spotlight
PArTS DESCrIPTION (see Fig� A)
Screw for terminal box
1
Lustre terminal
2
Unlock button
3
Assembly plate
4
Screws for assembly plate
5
Cable bushing
6
Dowels
7
Motion detector
8
(Modell City SH 8005 PIR IP 44, City LH 8005 PIR IP 44 and City LH 562405 PIR IP 44)

SAFETy INSTruCTIONS

Notice: Please read the following instructions before your install the lamp. Make sure that the
current is shut off before you connect the lamp. The lamp may only be installed by a qualified
professional.
warning: This lamp may not be used without all of the o-rings properly installed! LED lamps are
extremely bright. Under no circumstance should you look into the LED lamp as this can cause
permanent damage to the eyes.
A broken LED cover must be replaced with a Brennenstuhl LED protection disc prior to continuing
to use the lamp.

TECHNICAL DATA

Nominal voltage:
Nominal power:
Protection type:
Protection class:
The LED lamp is solely for normal use and not designed for raw operation.
Motion detector range:
Duration:
Ambient temperature:
INSTALLATION
Notice: The lamp must be installed on a dry, stable and solid surface in accordance with the
specifications in Fig. B. Ideally, the LED lamp should be installed 1.8 to 2.5 above the ground (see
Fig. B).
8
BA_City_LED-Premium_0486444_150313.indd 8
220–240 V~ 50 / 60 Hz
80 x 0,5 W LED
IP 44
I
approx. 180 ° and max. 10 meter, adjustable
adjustable from 10 (+/– 5) seconds up to 4 (+/– 1) minutes
–15 °C – + 40 °C
13.03.15 09:20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Premium city sh 8005 pir ip44Premium city lh 8005 ip44Premium city lh 562405 ip44Premium city lh 8005 pir ip44Premium city lh 562405 pir ip44City sh 8005 ip44 ... Mostrar todo

Tabla de contenido