Haier AS07NS3HRA Manual De Instruccion página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
Operation
Comfortable SLEEP
SLEEP
Press
button , the remote controller will
show
, and then achieve to the sleep function.
Press again this
SLEEP
be cancelled.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
O
1
C
higher than temp.setting.After another 1 hours,
temp.risesby 1
O
C
futher .The unit will run for further
6 hours then stops Temp. is higher than temp.setting
so that room temperature won't be too low for your
sleep.
SLEEP operation starts
1 hr
1 hr
Temp.setting
In COOL, DRY mode
2.In HEAT mode
1 hours after SLEEP mode starts, temp will become
O
2 C lower than temp.setting. After another 1 hours,
O
temp decrease by 2 C further. After more another
3 hours, temp.risesby 1 C further.The unit will run
for further 3 hours then stops.Temp. is lower than
temp. setting so that room temperature won't be too
high for your sleep.
Temp.setting
1 hr
1 hr
SLEEP
operation starts
3.In AUTO mode
The unit operates in corresponding sleep mode
corresponding sleep mode adapted to the
automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
6
button , the sleep function will
SLEEP operation stops
Approx.6hrs
O
Rises 1
C
O
Rises 1
C
Unit stop
O
Unit stop
O
Decreases 2
C
O
Decreases 2
C
3 hrs
3 hrs
O
Rises 1
C
SLEEP
operation stops
In HEAT mode
5. When quiet sleeping function is set to 8 hours the quiet
sleeping time can not be adjusted.When TIMER function is
set,the quiet sleeping function can't be set up.After the
sleeping function is set up,if user resets TIMER function, the
sleeping function will be cancelled; the machine will be in the
state of timing-on,if the two
time,
either of their operation time is ended first,the unit will
stop automatically,and the other mode will be cancelled.
Note
When TIMER function is set, the sleeping function can't be
set up .After the sleeping function is set up
TIMER function, the sleeping function will be cancelled; the
machine will be in the state of timing-on.
Note to the power failure resume:
Press the sleep button ten times in five seconds and enter
function after hearing four sounds.And press the sleep button
ten times within five seconds and leave this function after
hearing two sounds.
Power Failure Resume Function
If the unit is started for the first time, the compressor will not
start running unless 3 minutes have elapsed. When the power
resumes after power failure, the unit will run automatically,
and 3 minutes later the compressor starts running.
Healthy airflow Operation
1.Press
to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
Press
button to enter additional options,Press this
button continuously, the louvers location will cycle between
in the following three locations, to choose the swing location
what you needed,and then press
Healthy
airflow
upwarder
3.The cancel of the healthy airflow function
Press
button to enter additional options,Press this
button continuously, the louvers location will cycle between
in the following three locations again,and then press
button to cancel.
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote
controller.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
2.In cooling, it is better to select the
3.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
occur at the grille .
modes are set up at the same
,
if user resets
button to confirm.
Healthy
Present
airflow
position
downwarder
mode.

Hide quick links: