Using The Hob - Dometic EK 1600 Instrucciones De Uso

Hornillo de gas para automóviles y embarcaciones
Ocultar thumbs Ver también para EK 1600:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43

Using the hob

 Keep the hose connection between the gas appliance and the liquid gas
supply system as short as possible, and no longer than 750 mm.
 The entire hose connection must be accessible for inspection purposes.
 In particular, ensure that the hose does not affect the functionality of the
gimbal (no stress or kinks in all operating conditions).
 During operation, air vents with a free cross-section of at least 150 cm
must be present in the installation space. These vents can be closed, but
must be kept open when the device is in use.
➤ Connect the hob to the gas supply.
➤ Attach a sign above the hob with the following text:
"WARNING!
When cooking, it is necessary to provide additional ventilation, e.g. by
opening windows in the vicinity of the grill, hob or oven.
These devices must not be used for heating the room."
➤ Make sure that the hose line:
– Is not crushed or kinked.
– Is a safe distance from the burner.
➤ Open the valve on the gas bottle.
WARNING! Risk of injury!
!
Never check for leaks with a naked flame or near sources of
ignition.
➤ Check all connections with leak spray.
There are no leaks if no bubbles form.
7
Using the hob
7.1
Lighting the hob
WARNING! Risk of injury!
!
Never leave the hob unattended during operation.
The complete ignition process must be visible from above and must
not be hidden by pots placed on top of the hob.
12
Dometic EK 1600, EK 3200
²
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ek 3200

Tabla de contenido