Workplace requirements

Choose a suitable site for the operation. It must fulfill the regulations for workplace safety
applicable in your country and must provide a suitable electronic supply connection and pressure
air connection with 8-10bar.
The ground must be level and solid and capable to bear the machines weight.
Take care to position the machine so that it has at least 1m of free space around.
Fix the machine through the 4 bores in the machine base to the ground!

15.2.1 Electrical Connection

Dangerous electrical voltage! The machine may only be connected to the mains
supply and the associated checks carried out by a qualified electrician or under the
instruction and supervision of a qualified electrician!
The connection of the machine to the electric power supply and the following checks are to be
carried out by respectively certified electricians only!
The electronic connection of the machine is designated for operation with a grounded power
socket!
The connector plug may not be altered or manipulated!
A damaged cable has to be replaced immediately!
The supply net must be secured with at least 16A.
Check, whether the supply net voltage and frequency complies with the machine motors
requirements!

Compressed air connection

Connect the machine to compressed air supply at the compressed air connection (16). ATTENTION:
The ZI-RMM95 may be only operated with pressure levels between 8-10 Bar.

Test run

Check the function of the foot pedals and of the pressure air hose.
If you notice any malfunctions check all connections again
16

OPERATION

In order to avoid damages, use the provided mounting lever to initiate the demounting and
mounting of tyres.
The connecting area between tyre and rimbed, where the bed-breaker separates the tyre from
the rim, should always be lubricated with suitable lubricants to prevent the rim from damage.
Check for eventual prescribed running directions for tyre mounting of the tyre wall.
Tyres and rims must match together regarding their technical dimensions.
Always check the tyre extensively for any abnormalities like deformation, surface damage,
excessive or uneven wear etc.
before mounting it.
Always check whether tyre/rim requires special mounting procedures. For this inform yourself in
documentations etc. oft he respective manufacturer.
When inflating tyres, check tyre pressure and tyre form frequently.

Dismount tyre from the rim

Slowly release the air from the tyre.
Remove all balance weights and other foreign materials from the rim.
Lubricate the tyre bead with suitable lubricant or soap suds, before you separate the tyre from the
rim with the bead-breaker to prevent the tyre bead from damage.
Place the tyre to the tyre positioning plate (20), so that the bead-breaker (19) edge is max.
1cm far from the rim edge.