4 Operation

DE
Keep workpiece away from the demagnetizer before switching on.
u
Switch on the demagnetizer by pressing the operating switch to pos. 1.
u
The operating mode is indicated by the indication light.
Slowly move the workpiece (15 m/s to 20 m/s) from left to right or right
EN
u
to left over the demagnetizer pole plate.
After workpiece-end make sure that it is moved away sufficiently (min. 30 cm)
u
from the pole plate, otherwise a magnetization of the workpiece can occur.
Please ensure that when the demagnetising device is switched off, the workpiece is likewise ca.
u
30 cm away from the pole plate as otherwise it is not possible to rule out the workpiece being
FR
re-magnetised.
To prevent workpieces from scratching a thin sheet of carton or plastic may be
u
used between workpiece and pole plate.
The maximum height of the magnetic field is 75 mm.
u
If the workpiece is thicker and is magnetized on both sides, turn it around
u
IT
and demagnetize the opposite side.

5 Inspection and Maintenance

ES
Keep the device clean. Clean it with a damp cloth.
u
Check the table for damage before each use.
u
Check the presence and legibility of the type plate.
u
Check the cable and and plug weekly for any tear, damage or wear.
u
CZ
Store the demagnetizer in a dry and frost-free place.
u
PL
RU
ZH