STEINEL IS 2160 Instrucciones De Montaje página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
Functions
The system can be put into
operation once the sensor
8 sec. – 35 min.
2 – 2000 lux
Reach adjustment
Reach can be reduced by
tilting (70°) the sensor.
The sensor can be turned
Precision adjustment using shrouds
The adhesive shrouds
provided may be used
to adjust the sensor's
detection angle to suit
14
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
has been connected and
installed. Two setting con-
Switch-off delay
(time setting)
The chosen light 'ON' time
can be varied continuous-
ly from approx. 8 sec. to a
maximum of 35 min. The
shortest period, approx.
8 sec., is selected by
turning the control fully
clockwise. The longest
period, approx. 35 mins.
Twilight setting
(response threshold)
The chosen detector
response threshold can
be adjusted continuously
from approx. 2 lux to 2000
lux. Turning the control
fully clockwise will select
daytime operation at ap-
prox. 2000 lux.
horizontally through 40°
(only with swivel mount) to
align the detection zone
individual requirements.
This makes it possible,
for example, to blank out
neighbouring premises
trols are provided on the
bottom of the unit.
is selected by turning the
control fully anticlockwise.
It is recommended to
select the shortest time
for adjusting the detection
zone and for performing
the walk test. Any move-
ment in the detection
zone will re-activate the
time setting.
Turned fully anti-clock-
wise, the control is set to
dusk-to-dawn operation
at approx. 2 lux. When
adjusting the detection
zone and for the perform-
ance test in daylight, the
adjusting screw must be
turned fully clockwise.
(s. fig. page 4)
in exactly the way you
require.
(s. fig. page 4)
from detection or
specifically target paths.

Publicidad

Tabla de contenido
loading