Prior to installation
Preparing the wall
The wall must be flat and perpendicular.
Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.
Weight in kg:
Exhaust air
34,0
We reserve the right to construction changes within the
context of technical development.
Changing over from exhaust-
air to recirculating mode
Changing the electronic control system
to recirculating mode:
The standard factory setting is for
operation in exhaust-air mode.
To change the mode, the extractor hood
must have been connected up and
should be switched off.
1. Press and hold the 0 button.
2. While
is displayed, press the
{
button until
is displayed.
ã
When this has taken place, release the
buttons.
goes out shortly afterwards.
ã
The electronic control system will then
have been set to recirculating mode.
By repeating steps 1 and 2, you can
change the electronic control system
back to exhaust-air mode (

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow
Blue
Brown
Recirculating air
36,0
in display).
#
– Earth
– Neutral
– Live
If you fit your own plug, the colours of these
wires may not correspond with the identify-
ing marks on the plug terminals.
This is what you have to do:
1. Connect the green and yellow (Earth) wire
to the terminal in the plug marked 'E' or
with the symbol (
or green and yellow.
2. Connect the blue (Neutral) wire to the
terminal in the plug marked 'N' or
coloured black.
3. Connect the brown (Live) wire to the
terminal marked 'L', or coloured red.
The extractor hood and the screen may be
connected to correctly installed earthed
sockets only.
Preferably attach the earthed sockets
directly behind the flue duct (see installation
diagram).
An additional earthed socket is required
for connecting the screen to the power
supply.
The earthed socket should be
connected via its own circuit.
If the earthed socket is no longer
accessible following installation of the
extractor hood, ensure that there is a
permanently installed disconnector.
If it is necessary to wire the extractor
hood directly into the mains:
The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such devices
include circuit breakers and contactors.
If the connecting cable for this
appliance is damaged, the cable must be
replaced by the manufacturer or his custo-
mer service or a similarly qualified person in
order to prevent serious injury to the user.
Electrical data:
Are to be found on the name plate inside the
appliance after removal of the filter frame.
Before undertaking any repairs, always
disconnect the extractor hood from the
electricity supply.
Length of the connecting cable: 1.30 m.