AA
AB
AC
AI
AO
AP
Display AL.
In all welding processes, it numerically displays the
selections made via the selection key AE and adjusted
via the knob AI.
For the welding current (LED AD) it displays the amperes.
For the wire speed (LED AC) it displays the meters per
minute.
For the thickness (LED AB) it displays the millimeters.
For (LED AA) it displays the set program number.
In the service functions the following are selected: TRG,
SP, HSA, CrA, PrF, PoF, Acc, bb, L, Dp, PPF, Ito, Fac.
For the parameters within the service functions that are
shown on the display AM, see the paragraph on service
functions.
When the machine is in the warning mode, it displays
a flashing warning (exemple: OPN if the lateral panel is
open. When the machine is in the error mode it displays
Err.
Display AM.
Displays by the number: in synergic MIG the arc length
and in conventional MIG the welding voltage.
For the welding voltage (LED AH) it displays the Volts. For
the arc length (LED AHoff) it displays a number between
9.9 and +9.9, 0 being the recommened value.
For the parameters in the MIG service function, that are
shown on the display AM, see the paragraph on service
functions .
When the machine is in error mode it displays the
corresponding error code between 1 and 99.
Selection key AO.
Each time this key is pressed, the selected process is
shown by LED AP/AQ/AR.
AD
AE
AL
AF
Fig. 2
AQ
AR
AG
AH
AU
AV
LED AP Pulsed MIG.
Shows that the selected process is the synergic MIG
Pulsed.
LED AQ SYNERGIC MIG.
Shows that the selected process is synergic MIG.
LED AR CONVENTIONAL MIG.
Shows that the selected process is conventional MIG.
Selection key AU.
Each brief pressure selects 2 stages mode (MANUAL) and
the 4 stages mode (AUTOMATIC), the selection is shown
on the display AL.
In the 2 stages mode the machine begins welding when
the welding torch trigger is pressed, and stops when
released.
In the 4 stages mode to begin welding press and release
the welding torch trigger; to interrupt, you must press and
release it again.
Selection key AV. (JOB)
Saving and restoring of the stored processes.
To save a working condition (JOB), just hold down for at
least 3 seconds the key AV, the LED AZ glows, on the
display AL the abbreviation STO flashes and on display
AM the number of the first available position flashes.
Knob AN is used to select the saving position; press again
key AV until a sound will confirm that it has been saved
and the selected number stops flashing.
To restore the saved number just briefly press key AV and
restore the number by means of knob AN. Up to 99 pairs
od current/voltage values may be saved.
To delete a saved number, press for at least 3 seconds
AM
AN
AZ
AY
AW
5