6. Telephone line LED status
LED T1
Green on and steady
Flashing green
Flashing green/orange
Red steady
7. Backup mode
7.1 Mains power failure
After 5 minutes of power failure, TYDOM 2.0 sends a notification to the alarm
control unit. The alarm control unit beeps.
TYDOM 2.0 sends you a notification of the power defect and continues sending
alarms via the GSM connection for 24 hours.
It is no longer controllable remotely.
After the 24 hour period, TYDOM 2.0 switches to energy saving mode, no other
function is available.
As soon as the mains power supply is restored, an end of defect notification is
sent to the alarm control unit.
The battery is designed to backup 22 power failures for 10 years.
Power
failure
5 mn
TYDOM 2.0
beeps
every 10 seconds
During a power failure, the video transfer function is not available.
The transfer of video links will resume when the power and Internet access are restored.
System status
System accessible locally
and remotely
Good GSM signal and IP connection OK
GSM call in progress or IP connection in
progress
Weak GSM signal and IP connection OK
No IP address allocated or no
GSM signal
Backup mode
alert transmission
24 h
44
LED T1
Switches to
energy saving mode