Service And Spare Parts - Dometic CWP 5311 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
IF THE
WATER PURIFIER STOPS WORKING

Service and spare parts

Before calling service, use the trouble-shooting guide "If the water purifier stops working" to try to rectify the fault yourself. If service
is called in to solve a problem that is in this list, there is a risk that you will be responsible for the cost. The same applies if you have
used the appliance for a purpose other than that for which it is intended.
Note that electrical faults should always be rectified by a certified electrician.
Give the appliance's product and serial numbers according to the data plate (see fig. A). The plate is located on the back of the water
purifier.
You can record these details here:
PROD.NO ............................................................
SER.NO ................................................................
Purchase date ........................................................
A
TECHNICAL
Data
Dimensions:
- height
- depth
- width
Weight:
- on delivery
- filled with water
Capacity:
Inlet pressure:
Working temperature:
- ambient and water temperature
Electrical data:
Connection
Low voltage protection
Resetting low voltage protection
Power consumption (excl. pump output):
- during purification
- during heating
- in standby
Fuse, slow blow
Pump current, max:
Requirements on
The tank must be filled with municipal water. In standing water (tank water) there is a risk of bacterial growth. The water purifier is
intended to purify the tank water.
Turbidity
Chlorine
Organic content
14
DATA
feed water to water purifier
< 7.5 FNU
4 mg/litre
< 1 mg/litre
340 mm
140 mm
290 mm
3.0 kg
3.7 kg
3.8 (±0.8) litres/minute
0.3-5 bar (30-500 kPa)
2 - 43 °C
12-24 V DC
9 V
10 V
10 W
12 W
1 W
6.3 A
5 A
0.84 (±0.18) gpm (UK)
5-72 PSI

Publicidad

Tabla de contenido
loading

Tabla de contenido