Parámetro
A184 [Load Loss Level]
A185 [Load Loss Time]
A186 [Stall Fault Time]
A187 [Bus Reg Mode]
A188 [Skip Frequency 1]
A189 [Skip Freq Band 1]
A190 [Skip Frequency 2]
A191 [Skip Freq Band 2]
A192 [Skip Frequency 3]
A193 [Skip Freq Band 3]
A194 [Compensation]
A195 [Reset Meters]
A196 [Testpoint Sel]
A197 [Fault Clear]
A198 [Program Lock]
A199 [Motor NP Poles]
A200 [Motor NP FLA]
Parámetros del grupo de tarjetas de relés auxiliares
No.
Parámetro
R221
[Relay Out3 Sel]
R224
[Relay Out4 Sel]
R227
[Relay Out5 Sel]
R230
[Relay Out6 Sel]
R233
[Relay Out7 Sel]
R236
[Relay Out8 Sel]
R222
[Relay Out3 Level]
R225
[Relay Out4 Level]
R228
[Relay Out5 Level]
R231
[Relay Out6 Level]
R234
[Relay Out7 Level]
R237
[Relay Out8 Level]
Parámetro [Relay OutX Select]
6
7
8
9
10
12
R239 [Aux Motor Mode]
R240 [Aux Motor Qty]
R241
[Aux 1 Start Freq]
R244
[Aux 2 Start Freq]
R247
[Aux 3 Start Freq]
R242
[Aux 1 Stop Freq]
R245
[Aux 2 Stop Freq]
R248
[Aux 3 Stop Freq]
Mín./ Máx.
Visualización/opciones
0.0/Drive Amps
0.1 Amps
0/9999 Seg
1 Seg
0/5
0 = "60 Seconds"
1 = "120 Seconds"
2 = "240 Seconds"
0/1
0 = "Disabled"
0/320 Hz
1 Hz
0.0/30.0 Hz
0.1 Hz
0/320 Hz
1 Hz
0.0/30.0 Hz
0.1 Hz
0/320 Hz
1 Hz
0.0/30.0 Hz
0.1 Hz
0/3
0 = "Disabled"
1 = "Electrical"
0/2
0 = "Ready/Idle"
1024/65535
1
0/2
0 = "Ready/Idle"
0/3
0 = "Unlocked"
1 = "Locked" (All)
2/40
1
0.1/(Drive Amps × 2)
0.1 Amps
Mín./ Máx.
Visualización/opciones
0/23
0 = "Ready/Fault"
1 = "At Frequency"
2 = "MotorRunning"
3 = "Hand Active"
4 = "Motor Overld"
5 = "Ramp Reg"
6 = "Above Freq"
7 = "Above Cur"
8 = "Above DCVolt"
0.0/9999 Hz
0.1
[Relay OutX Level], mín./máx.
0/320 Hz
0/180%
0/815 Volts
0/100%
1/180 grados
0/1
0/1
0 = "Disabled"
1/6
1 = "1 Aux Mtr"
2 = "2 Aux Mtr"
3 = "3 Aux Mtr"
0.0/320.0 Hz
0.1 Hz
0.0/320.0 Hz
0.1 Hz
Español-23
3 = "360 Seconds"
4 = "480 Seconds"
5 = "Flt Disabled"
1 = "Enabled"
2 = "Mechanical"
3 = "Both"
1 = "Reset MWh"
2 = "Reset Time"
1 = "Reset Fault"
2 = "Clear Buffer"
2 = "Locked" (Not Network)
3 = "Locked" (P035, A170)
Opción
predeterminada
9 = "Above Anlg 2"
0
10 = "Above PF Ang"
11 = "Anlg In Loss"
12 = "ParamControl"
13 = "Retries Exst"
14 = "NonRec Fault"
15 = "Reverse"
16 = "Logic In 1"
17 = "Logic In 2"
23 = "Aux Motor"
0.0
1 = "Enabled"
0
4 = "1 Mtr + Swap"
1
5 = "2 Mtr + Swap"
6 = "3 Mtr + Swap"
50.0 Hz
25.0 Hz
Opción
predeterminada
0.0
(inhabilitado)
0 (inhabilitado)
0
1
0 Hz
0.0 Hz
0 Hz
0.0 Hz
0 Hz
0.0 Hz
3
0
1024
0
0
4
Amps nom.

Publicidad