All operating elements and connections described
GB
can be found on the fold-out page 3.
1 Operating Elements and Connections
1 Signal input as a phono jack
2 Signal input as a 6.3 mm jack,
balanced
3 Signal input as an XLR jack,
balanced
4 Control GAIN to adapt the input level from -30 dB
to +6 dB
5 Rotary switch HF ADJUST to correct the high
range from -2 dB to +1 dB
6 Mains switch POWER
7 Support for the mains fuse;
only replace a blown fuse by one of the same type
8 Cable for connection to a mains socket (230 V~/
50 Hz)
2 Safety Notes
The unit corresponds to all relevant directives of the
EU and is therefore marked with
WARNING The unit is supplied with hazardous
mains voltage. Leave servicing to
skilled personnel only. Inexpert han-
dling of the unit may cause an electric
shock hazard.
It is essential to observe the following items:
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient temperature
range 0 – 40 °C).
G
Do not place any vessels filled with liquid, e. g. drink-
ing glasses, on the unit.
G
The heat being generated in the unit must be carried
off by air circulation. Therefore, the air vent (bass
reflex opening) must not be covered.
G
Do not set the unit into operation, or immediately dis-
connect the mains plug from the mains socket if
1. there is visible damage to the unit or to the mains
cable,
2. a defect might have occurred after a drop or simi-
lar accident,
3. malfunctions occur.
The unit must in any case be repaired by skilled per-
sonnel.
G
A damaged mains cable must only be replaced by
skilled personnel.
G
Never pull the mains cable to disconnect the mains
plug from the mains socket, always seize the plug.
6
G
G
G
.
3 Applications
This high-quality pair of active speakers is suitable for
HiFi applications, as a monitor system in the home
recording studio, for AV presentations, as High End PC
speakers, and for all other applications in smaller
rooms requiring an excellent sound reproduction
which is rich in detail.
speaker with glass fibre cone and a 2.54 cm (1") dome
tweeter, controlled in each case by a separate power
amplifier. The speakers are provided with magnetic
shielding. The high range can be adapted e. g. to the
acoustics of the room via a rotary switch.
overload and with protective circuits against short cir-
cuit, overheating, and DC voltage content at the outputs.
4 Setting-up and Connecting
Place the speakers on an even surface and align them
to the ears of the listener. The tweeters should be at
earʼs height, if possible.
corners as this will falsify the frequency response and
impair the heat dissipation of the installed amplifier.
netic fabric cover. When transporting the speakers,
make sure that the cover does not come off.
For cleaning only use a dry, soft cloth, never use
chemicals or water.
No guarantee claims for the unit and no liability for
any resulting personal damage or material damage
will be accepted if the unit is used for other purposes
than originally intended, if it is not correctly con-
nected, operated, or not repaired in an expert way.
Important for U. K. Customers!
The wires in this mains lead are coloured in ac cord -
ance with the following code:
blue = neutral
brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug, pro-
ceed as follows:
1. The wire which is coloured blue must be con-
nected to the terminal in the plug which is marked
with the letter N or coloured black.
2. The wire which is coloured brown must be con-
nected to the terminal which is marked with the
letter L or coloured red.
If the unit is to be put out of operation defini-
tively, take it to a local recycling plant for a
disposal which is not harmful to the environ-
ment.
Each speaker system has a 16 cm bass-midrange
The amplifiers are equipped with a limiter against
Do not place the speakers too close to walls or in
The speakers are supplied with a detachable mag-