Description And Operation; Warning - Caution; Installation - Vortice TELENORDIK 5TR Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
ENGLISH

Description and operation

TELENORDIK 5TR is an infrared remote control unit
with timer, for remote control of all Vortice reversible
ceiling fans, with and without light.
The appliance comprises two parts, a receiver and a
transmitter. TELENORDIK 5TR can be used: to
operate the fan at 5 different speeds, to reverse the
fan, and to turn the light on / off in versions fitted
with a light. In addition, the timer incorporated in
TELENORDIK 5TR can operate the fan for one hour
at the selected speed and in the selected direction.
Warning!
!
precautions that must be taken to avoid
personal injury
• Do not use this appliance for purposes other than
the proper purposes described in this manual.
• After removing the appliance from its packaging,
ensure that it is complete and undamaged. If in
doubt contact a professionally qualified electrician
or Vortice. Do not leave packaging within the reach
of children or infirm persons.
• Certain fundamental rules must be observed when
using any electrical appliance, including: a) never
touch appliances with wet or damp hands; b) never
touch appliances while barefoot; c) never allow
children or infirm persons to operate appliances
unattended.
• Do not us the appliance where flammable vapours
are present (spirit, insecticides, petrol, etc.)
• Store the appliance out of reach of children and
infirm persons after disconnecting it from the power
supply.
• Any modification made to the appliance
automatically invalidates the warranty and absolves
the manufacturer from all liability.
Caution!
This symbol indicates
!
precautions that must be taken to avoid
damage to the appliance
• Do not make modifications of any kind to this
appliance.
• Do not expose this appliance to the weather (rain,
sun, etc.).
• Do not immerse the appliance or any of its parts in
water or other liquids.
• Regularly inspect the appliance for visible defects.
If any faults are found, do not operate the
appliance; contact Vortice* immediately.
• If the appliance does not function correctly or
develops a fault, contact Vortice* immediately.
Ensure that only genuine original Vortice spares
are used for any repairs.
• Should the appliance be dropped or suffer a heavy
blow, have it checked by Vortice* immediately.
• The appliance must be installed by a
professionally qualified electrician.
* or an authorized Vortice dealer if you are outside the UK-Ireland territory
8
8
This symbol indicates
• The electrical system to which the appliance is
connected must conform to applicable standards.
• The appliance must be connected to an efficient
earthing system in accordance with applicable
electrical safety standards. If in doubt, ask a
qualified electrician to check your system.
• The electrical power supply/socket to which the
appliance is to be connected must be able to
provide the maximum electrical power required by
the appliance. If it does not do so, arrange for a
qualified electrician to make the necessary
modifications.
• Use a multi-polar switch with a minimum contact
gap of 3 mm or more to install the appliance.
• Switch off the appliance at the installation's main
switch: a) if the appliance does not function
correctly; b) before cleaning the outside of the
appliance, c) if the appliance is not to be used for
any length of time.
• The internal connection cable in this appliance
must never be replaced by the user, but only by a
qualified electrician.
• Remove the batteries from the transmitter and
dispose of them at a designated battery collection
point before scrapping the transmitter.

Installation

(see drawings on page 29)
The receiver is set up to be fitted on all Vortice
reversible ceiling fans with a max. rod length of
500 mm. If it is fitted on a longer rod, replace the
six-pole cable provided with another of the same
type and a suitable length.
If it is installed on a shorter rod, adapt the length
of the cable by cutting it at the free end that is
not connected to the receiver.
FITTING ON REVERSIBLE CEILING FANS
WITHOUT A LIGHT TO BE FITTED
1) Insert the remote control receiver A and the cover
G into the fan extension rod (Fig.2).
2) Insert the connection cable C, already wired to
the receiver, into the pipe until it comes out of the
hole B. If TELENORDIK 5TR is installed on a new
ceiling fan, do not fit the cable raceway that,
according to the fan instruction booklet, should be
fitted in hole B (Fig. 3); if TELENORDIK 5TR is
installed on a ceiling fan that is already in place,
remove the cable raceway fitted in hole B (Fig. 3).
3) Connect the connection cable C to the fan
terminal board, as indicated: 1 = blue, 2 = grey,
= yellow-green, 5 = white.
4) Connect the power supply wires to terminal board
E in accordance with the L, N,
on the base of the receiver near the terminal board
itself (Fig. 4).
5) Insert the receiver, together with the cover that
holds it, against the ceiling or near it, and fasten
screw M without tightening it too much (Fig. 5).
6) The remote control transmitter support can be
fastened to the wall by drilling a
inserting the wall plug provided (Fig.6).
32)
symbols shown
6 mm hole and

Publicidad

Tabla de contenido
loading

Tabla de contenido