8
Troubleshooting
Fault
Device cannot be switched on
Plotter does not react to data sent by the
PC.
The plotter starts up, but labelling is not
created.
Poor printing, uneven line thickness,
missing parts of labels
1) Only use detergents named as accessories (see Chapter 10).
Tab. 8.1 Troubleshooting MCP Plus 2
If there is a fault that cannot be remedied
using the measures described above, please
contact the Weidmüller Service Depart-
ment.
32
Possible cause
Power supply not connected
No power supply
Power supply faulty (green LED on power
supply does not light up even though the power
supply is connected)
USB cable not connected properly
Device driver not correctly installed
Plotter pen dried out
Plotting pen empty
Contamination on plotter tip
Recommended action
Check that the power supply is connected to
the plotter and to the power supply.
Have the socket checked by an electrician.
If necessary, switch to another socket.
Replace the power supply.
Check whether the USB cable is properly
connected to the plotter and the PC.
If necessary, replace the data cable.
Check whether the device driver is installed on
the PC.
If necessary, install the device driver.
Use the writing function.
If necessary, remove the plotter pen from the
pen station and clean the tip carefully with a
soft cloth dipped in cleaning fluid
Remove the plotter pen from the pen station
and refill or replace it.
Remove the plotter pen from the pen station
and clean the tips carefully with a cloth dipped
in cleaning fluid
.
1)