1 Introduction
1.1
INSTALLATION
MANUAL
The present document applies to chargers in the
CRISTEC CPS range of battery chargers listed
below.
Power
U/I Rating
(Watts)
12V 06A
24V 03A
12V 10A
24V 05A
12V 12A
This manual is intended for users, installers and
equipment maintenance personnel who must ensure
they understand the present document before any
intervention on the charger.
1.2
VALIDITY OF THIS DOCUMENT
This document is the property of CRISTEC ; all the
information contained in this document applies to the
accompanying product. The company reserves the
right to modify the specifications without prior
notice.
1.3
GUARANTEE
Failure to comply with the rules for installation and
operation cancels the manufacturer's guarantee and
absolves CRISTEC of all responsibility.
The period of guarantee is 36 months. It applies to
parts and labour for any equipment returned to the
factory.
Only parts acknowledged to have been defective
from the outset will be replaced under the guarantee
Equipment which has been misused or damaged by
errors in connections, impacts, falls or which is
defective from having been worked upon by persons
other than those authorised by CRISTEC Industries.
Equipment which has been installed or operated at
variance with procedures outlined in the manual
provided with each unit.
Under no circumstances, can any indemnity be
granted by this warranty.
AND
OPERATING
CRISTEC
Reference
CPS 70-1A
70
CPS 70-2A
CPS 120-1A
120
CPS 120-2A
140
CPS 140-1A
CPSDED
This warranty does not apply to the following
terms :
Transportation and packaging charges to and from
the factory or authorised service station.
Damage sustained in shipment, apparent or
concealed.
Claims for such damage must be reported and filed
with the carrier by the person receiving the
equipment.
1.4
BRIEF PRESENTATION
Chargers in the CPS (charge, programmable,
selective) range provide specific charging for 1 or 2
battery's banks in accordance with the battery
manufacturers' specifications.
An internal switch selects the type of battery :
Lead/Antimony (ANT) or Lead/Calcium (CAL).
Entirely automatic with built-in charge distribution,
they can remain permanently connected to the
batteries in complete safety and do not need to be
disconnected when starting the engine.
The timed Boost function, which allows the batteries
to be charged more quickly (6 hours ± 30 minutes),
may be activated or inhibited by means of an internal
switch as the user wishes:
"BOOST ON" position to enable Boost
"BOOST OFF" position to disable Boost
CPS chargers are protected against polarity reversal
and transient short-circuits.
Accepting a wide range of input frequencies and
voltages, they work from electricity generating sets
and may be connected to international marinas within
the specified tolerance range (115/230Vac ± 15%,
selected by internal jumper).
Two indicator lamps on the front panel show the
state of the charger :
Green LED
Yellow LED
ON"
CPS chargers are supplied in a metal case with IP22
protection rating. The overhanging cover and hood
protect the charger from running water.
The equipment is designed to work in a marine and
mobile environment.
All of the CPS range output a filtered and regulated
voltage of 12 or 24 V. In the event of battery
disconnection, the charger supplies the loads without
damage.
Page 13
Connection to ac mains
Flashing : charging "BOOST