Problem Solving
Problem Solving
PROBLEM
PROBABLE CAUSE
Unit fails to start
a. Power Failure
b. Tripped Circuit Breaker
c. Blown Fuse
d. Electrical Fault in cooler
Filter Pads not
a. Pump Seized
wetting.
b. Electrical fault with pump
Filter pads too
a. No water restrictor
wet
b. Electrical fault with pump
c. Needs smaller restrictor
d. High voltage in your area
Water leaking
a. Float Valve Leaking
from overflow
b. Drain from Pads
a. Loose Delivery Tube
b. Break in tubing
Water Droplets in
c. Pump appears to deliver
air stream
d. Bleed nozzle is blocked
Excessive
a. Not enough air flow
humidity
b. Inadequate Exhaust
a. Dirty Filters
nadequate
I
b. Dry Filters
Cooling
Unpleasant Odor
a. Unit located near odor
b. Algae in water tank
Rapid formation
a.
of white deposits
b.
on pads
excessive water to pads
source
Insufficient bleed rate
High mineral content in
water supply
ANY FURTHER PROBLEMS PLEASE CONTACT YOUR
BONAIRE CUSTOMER CARE LINE ON 1-800-939-2983
REMEDY
a. Wait for power to be turned on.
b. Reset circuit breaker
c. Replace
d. Call Bonaire Care Line
a.
Extension cord dropping voltage
b. Maintenance page. See Pump section.
c.
Adjust restrictor
d.
Call Bonaire Care Line
a. Maintenance page. See Pump section.
b.
Adjust restrictor
c.
Call Bonaire Care Line
a. Adjust or replace float valve if necessary
b. Normal Operation – adjust float level
a. Check and tighten
b Replace as necessary
c. Check the condition of the filter pad. Wash if pad
shows heavy build-up of minerals
d. Clean bleed nozzle
a Increase fan speed
b. Provide more open area to exhaust stale air by
opening windows and doors in adjacent rooms.
a. Clean
b. Check control set on COOL mode.
Check water delivery system. Adjust if necessary.
a. Remove source
b. Clean tank and refill with fresh water.
a. Bleed off should be checked to see if bleed
nozzle is blocked, clear if necessary and clean
pad.
b. Increase
the
maintenance may be required.
27
bleed
rate.
More
regular