MINI MANUAL
Step 1
Remove the pierced CO² cylinder by turning
it anti-clockwise and discard it in an
environmentally friendly manner.
Step 2
Push the lever back into its slot and
clip the new manual indicator in place.
Step 3
Ensure the black CO² cylinder seal is fitted correctly.
• Do not detach the inflator from the lifejacket.
• Before commencing the rearming procedure
ensure you have the correct re-arming kit with
the correct size CO² cylinder and that the
lifejacket is dry.
• Ensure the automatic cartridge in the re-arming
kit is within its Replace By Date
Step 4
Ensure the CO² cylinder cap has not been pierced and
then screw it clockwise into the UML Mini Manual.
Tighten up, hand tight.
15
REARMING