Descargar Imprimir esta página

Fein ALG30 Manual De Instrucciones página 9

Ocultar thumbs Ver también para ALG30:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
OBJ_BUCH-0000000028-001.book Page 9 Tuesday, February 1, 2011 1:44 PM
Meaning of the LED indicator.
LED indicator
continuous yellow
light
green flashing light The rapid charging is active.
continuous green
light
red flashing light
green flashing light
and red flashing
light
Repair and customer service.
Once per week; more often in case of frequent usage:
– Keep the contacts in the slide-on shoe clean.
– Clean electrical contacts only dry.
– Pay attention that metal chips do not enter the hous-
ing of the battery charger.
When the battery charger's power cord is damaged, it
must be replaced by FEIN or by an authorized FEIN Serv-
ice Agent, in order to avoid hazardous situations.
Warranty and liability.
The warranty for the product is valid in accordance with
the legal regulations in the country where it is marketed.
In addition, FEIN also provides a guarantee in accordance
with the FEIN manufacturer's warranty declaration.
The delivery scope of your battery charger may include
only a part of the accessories described or shown in this
Instruction Manual.
Declaration of conformity.
FEIN declares itself solely responsible for this product
conforming with the relevant provisions given on the last
page of this Instruction Manual.
Environmental protection, disposal.
Packaging, worn out battery chargers and accessories
should be sorted for environment-friendly recycling.
Dispose of batteries only when discharged.
Meaning
The battery charger is ready for operation; mains voltage is given.
The rapid charging is completed. Trickle charging is active
(only NiCd/NiMH batteries).
Charging not possible due to the following possible reasons:
– Contacts contaminated. Improvement measure: Clean the contacts by inserting and
removing the battery several times.
– The battery is defective. Improvement measure: Replace the battery!
The battery temperature is not within the charge-temperature range of 0 °C to
+45 °C. The rapid charging procedure starts as soon as the battery reaches the
allowable charge-temperature range.
For batteries that are not completely discharged, insulate
the terminals with tape as a protective measure against
short-circuiting.
en
9

Publicidad

loading