Hold select 2..4 sec untill led flashes and select the function below
Select =>
Inverter
No function
DEPT 1
level 1
DEPT 2
DEPT 3
DEPT 4
DEPT 5
DEPT 6
DEPT 6
DEPT 7
DEPT 7
Hold select & setup 2 to 4 sec untill both leds flashes
Inverter
SELECT & SETUP
No function
DEPT 1
level 2
DEPT 2
DEPT 3
DEPT 4
DEPT 5
DEPT 6
DEPT 6
20
MICC Installer level
Volt-Amp
M01
Set Low Voltage Level
Low Battery Signal
11vdc / 22vdc
M02
Set dischage Floor
35% of C.ahr
20% .. 50%
0-10-20-30 minutes
M03
Set level full charge
80% of C.ahr
70%..90%
M04
Set min. require run time
10 min
5 min .. 90 min
M05
Exit level
Program level - advanced settings
Volt-amp
M06
Test Low Batt. mode
on - off
M07
Change C.E.F. Manual
Exit level
Ahr-time
Charger
A01
Battery Capacity
Current Control
200 ah
100% amp
40 .. 9990 ah
10%..100%
A02
Average Time
Consumtion
0 minutes
A03
Return amps
6% of C.ahr
1%..10%
A04
Float level
13.1V / 26.2V
A05
Reset Ahr to 0000
Press setup
A06
A06
Battery type
Battery type
12 /24V
12 /24V
A07
A07
Exit level
Exit level
Figura 8: Diagrama de ajustes nivel de instalador
Ahr-time
Charger
A08
Change Peukert
No function
exponent 1,27
1,01 to 1,50
A09
actual read out
0.7... 0.99
A10
Exit level
Figura 9: Diagrama de ajustes, ajustes avanzados
Set-up
Set-up
C01
F01
Sleep mode
Sleep mode
On / Off
On / Off
F02
C02
Low Bat. Contact
Exit level
Low Bat. Contact
On / Off
On / Off
F03
LED is switch
LED is switch
On / Off
On / Off
F04
HFC mode
HFC mode
On / Off
On / Off
F05
Exit level
Set-up
Set-up
F06
Reset to factory setting
Reset to factory setting
level 2
Press setup
Press setup
F07
Reset all historical data
Reset all historical data
Press setup
Press setup
F08
Exit level
Exit level
Julio 2005 / Masterlink MICC / ES
F01
F02
F03
F04
F06
F07
F08