Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe PuraVida 15472000 Modo De Empleo/Instrucciones De Montaje

Ocultar thumbs Ver también para PuraVida 15472000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
Fault
Insufficient water
Mixer stiff
Mixer dripping
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
150±16 mm
cold right - hot left
max. 70°C / 4 min
Cause
- Shower filter seal dirty
- check valve hasn't moved back
- Cartridge defective, calcified
- Cartridge defective
- Flow limiter in handshower isn't
removed
- Filters are dirty
- check valve hasn't moved back
Assembly see page 31
Safety against backflow
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Maintenance (see page 36)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions (see page 34)
Flow diagram (see page 34)
Spare parts (see page 32)
Operation (see page 35)
Cleaning (see page 36) and en-
closed brochure
Test certificate (see page 36)
Remedy
- Clean filter seal between shower
and hose
- Exchange check valves
- Exchange cartridge
- Exchange cartridge
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange check valves

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Puravida 15472400Puravida 15672000Puravida 15672400

Tabla de contenido