Dometic PERFECTPOWER DCC 1224-10 Instrucciones De Montaje página 21

Transformador de carga y tensión
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
PerfectCharge
Set float voltage
You can use the DIP switches S3 and S4 to set the float voltage in the U phase (float).
S3
ON
OFF
ON
OFF
Set charging mode
!
WARNING! Danger of explosions!
Use only the charging mode appropriate for your battery type. If neces-
sary inquire at a specialist workshop.
You can set the charger mode using the S5 and S6 DIP switches.
S5
ON
OFF
ON
OFF
EN
S4
ON
ON
OFF
OFF
S6
Charger Mode
ON
IU0U- charging
Refer to chapter "Battery charging function" on
page 16.
ON
Constant voltage 1
The battery charger works as a constant voltage
source, where the value of the voltage corresponds
to the set charging end voltage.
OFF
Constant voltage 2
The battery charger works as a constant voltage
OFF
source, with the value of the voltage corresponding
to the set floating voltage.
Use charging converter
Float voltage
12 V
13.8 V
13.5 V
13.2 V
24 V
27.6 V
27.0 V
26.4 V
21