Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

ALL ON
Turns on all outlets. Turn on is immediate with no delay.
Send to UPS:
!ALL_ON<CR>
If power is not switched off due to low battery conditions:

Action:

Turn on Outlet Bank 1
Response from UPS:
$BANK 1 = ON<CR>
If UPS battery level > Shutoff Threshold
Action:
Turn on Outlet Bank 2
Response from UPS:
$BANK 2 = ON<CR>
If UPS battery level < Shutoff Threshold
Action:
Turn off Outlet Bank 2
Response from UPS:
$BANK 2 = OFF<CR>
$BATTERY = charge%<CR>
Action:
Activate Power Button
Response from UPS:
$BUTTON = ON<CR>
ALL OFF
Turns off all outlets. Turn off is immediate with no delay.
Send to UPS:
!ALL_OFF<CR>
Action:
All outlets will turn off
Response from UPS:
$BANK 1 = OFF<CR>
Response from UPS:
$BANK 2 = OFF<CR>
Response from UPS:
$BUTTON = OFF<CR>
SWITCH OUTLET BANK
Turns a specific outlet bank on or off. Switching is immediate with no delay.
Send to UPS:
!SWITCH bank state<CR>
bank = {1, 2}
state = {ON, OFF}
Example: !SWITCH 2 ON<CR> (turns on outlet bank 2)
If power to bank 1 is switched:
Action:
Switch power to Outlet Bank 1
Response from UPS:
$BANK 1 = state<CR>
If power to bank 2 is switched AND battery level > Shutoff Threshold:
Action:
Switch power to Outlet Bank 2
Response from UPS:
$BANK 2 = state<CR>
If UPS battery level > Shutoff Threshold
Action:
Turn on Outlet Bank 2
10