Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with Aux. or Emergency Heat)
Systems with up to 3 Stages Heat, 2 Stages Cool
Heat Only Systems
Millivolt Heat Only Systems - Floor or Wall Furnaces
Cool Only Systems
Hydronic (Hot Water) Zone Heat - 2 Wires
Hydronic (Hot Water) Zone Heat - 3 Wires
SPECIFICATIONS
Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° to 90°F (7° to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . . 32° to +105°F (0° to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -4° to +150°F (-20° to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . . 3.4"H x 4.4"W x 1.3"D
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
Index
Blue Single 1/1 Stage Thermostat with
Automatic Heat/Cool Changeover Option
Installation and Operating Instructions for Model:
Model
1F80-0471
1F86-0471
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
Page
spilled mercury and place in a sealed container. For proper
2
disposal of a product containing mercury or a sealed
2
container of spilled mercury, place it in a suitable shipping
3
container. Refer to www.white-rodgers.com for location to
4
send product containing mercury.
6
6
8
www.white-rodgers.com
Single Stage or Heat Pump
Programming Choices
5/2 Day 5/1/1 Day Non-Programmable
Non-Programmable
1F80-0471 Thermostat
PART NO. 37-6749D
Replaces 37-6749C
0902

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Emerson White Rodgers 1F80-0471

  • Página 1: Tabla De Contenido

    Blue Single 1/1 Stage Thermostat with Automatic Heat/Cool Changeover Option Single Stage or Heat Pump Installation and Operating Instructions for Model: Save these instructions for future use! Model Programming Choices FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS 1F80-0471 5/2 Day 5/1/1 Day Non-Programmable CONTROL COULD CAUSE PERSONAL INJURY AND/OR...
  • Página 2: Installation

    INSTALLATION Batteries WARNING 2 "AA" alkaline batteries are included in the thermostat. To in- stall the batteries, pull the battery door as shown by the arrow Thermostat installation and all components of the and lift open. Using the polarity indicated inside the battery control system shall conform to Class II circuits per door, insert the batteries.
  • Página 3: Thermostat Quick Reference

    THERMOSTAT QUICK REFERENCE Figure 4 – Home Screen Display Home Screen Description Room Time Temperature Setting Day of Week Temperature Displays the power level of the 2 "AA" batteries: indicates good power level. Temperature Up/Down indicates batteries at about half power. “Change ”...
  • Página 4: Installer Confi Guration Menu

    INSTALLER/CONFIGURATION MENU With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press to change an item option.
  • Página 5 INSTALLER/CONFIGURATION MENU 4) Energy Management Recovery: (this step is skipped if 9) System Mode Confi guration – This thermostat is confi gured confi gured to be non-programmable). for Heat and Cool with Auto changeover (SYSTEM switch with Energy Management Recovery (E) On enables the ther- Cool Off Heat Auto) default.
  • Página 6: Operating Your Thermostat

    OPERATING YOUR THERMOSTAT IMPORTANT! Choose the Fan Setting (Auto or On) Manual Operation (Bypassing the Program) Programmable Thermostats Set the FAN Switch to Auto or On. Fan Auto is the most commonly selected setting and runs the Press and the HOLD button and adjust the tem- fan only when the heating or cooling system is on.
  • Página 7 PROGRAMMING (For Programmable Model Only) Energy Saving Factory Pre-Program The 1F80-0471 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button. The table below shows the factory set heating and cooling schedule for all days of the week.
  • Página 8: Troubleshooting

    HVAC service person for additional suggestions. HOMEOWNER HELP LINE: 1-800-284-2925 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mark www.white-rodgers.com of Emerson Electric Co.
  • Página 9 Termostato Blue Single 1/1 Stage con opción de conmutación calor/frío automática Una sola etapa o bomba de calor Instrucciones de instalación y uso para el modelo: ¡Conserve estas instrucciones para consultarlas en cualquier momento! Modelo Opciones de programación EL NO LEER Y SEGUIR CON CUIDADO TODAS LAS INSTRUCCIONES ANTES DE INSTALAR O UTILI- 1F80-0471 5/2 días...
  • Página 10: Instalación

    INSTALACIÓN hasta abajo, vuelva a engancharla en su lugar. Para cambiar las ¡ADVERTENCIA! pilas, coloque el sistema en OFF y siga las instrucciones anteriores. La instalación del termostato y de todos los componentes del Figura 1 – Puerta del compartimiento de las pilas abierta sistema de control debe ajustarse a las normas del código NEC para los circuitos Clase II.
  • Página 11: Descripción De La Pantalla Principal

    GUÍA DE REFERENCIA RÁPIDA DEL TERMOSTATO Figura 4 – Pantalla principal Descripción de la pantalla principal Temperatura Hora ambiente Temperatura Día de la semana de ajuste Muestra el nivel de carga de las 2 pilas "AA": indica buen nivel de carga. indica que a las pilas les queda Subir/Bajar temperatur aproximadamente la mitad de la...
  • Página 12: Menú Instalador/De Configuración

    MENÚ INSTALADOR/DE CONFIGURACIÓN Con el termostato en Heat, Cool o Auto, en operación normal, presione el botón Menu durante 5 segundos como mínimo. La pantalla mostrará la opción 1 tal como se describe en la siguiente tabla. Presione Menu para pasar a la siguiente opción del menu. Presione para cambiar la opción.
  • Página 13 MENÚ INSTALADOR/DE CONFIGURACIÓN Cuando esta función está en OFF (desactivada), no se realizarán 9) Confi guración del modo del sistema – Este termostato está cambios cuando el sistema de enfriamiento está funcionando de confi gurado para calor y frío con opción predeterminada de forma continua durante los períodos de alta demanda.
  • Página 14: Cómo Usar El Termostato

    CÓMO USAR EL TERMOSTATO ¡IMPORTANTE! Elija la confi guración del ventilador (Auto/On) Operación manual (omisión del programa) Modo programable Coloque el interruptor FAN en Auto (automático) u On (activado). Presione y el botón HOLD y ajuste la temperatura Auto es la confi guración más comúnmente seleccionada y hace cuando lo desee.
  • Página 15: Pre-Programación De Ahorro De Energía De Fábrica

    PROGRAMACIÓN (sólo para el modelo programable) Pre-programación de ahorro de energía de fábrica Los termostatos 1F80-0471 están programados con los ajustes de ahorro de energía indicados en la siguiente tabla para todos los días de la semana. Si este programa es adecuado para sus necesidades, simplemente ajuste el reloj del termostato y presione el botón RUN. La siguiente tabla muestra la programación de calefacción y enfriamiento ajustada de fábrica para todos los días de la semana.
  • Página 16: Solución De Problemas

    LÍNEA DE AYUDA PARA EL USUARIO: 1-800-284-2925 White-Rodgers es una división de Emerson Electric Co. El logotipo de Emerson es una marca comercial y una marca de servicio de www.white-rodgers.com Emerson Electric Co.

Este manual también es adecuado para:

White rodgers 1f86-0471

Tabla de contenido