6 Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the
device with a damp cloth. Do not install the device in a dust flow and avoid
build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they
must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
7 Connection configurations
MF1: -1 / +4
MF1: -2 / +5
8 Service/Maintenance
Repairs are not possible. The approval expires if the device is repaired or
modified by a person other than the manufacturer. The most important
data from the approval are listed.
73024998a
© Elster GmbH | All rights reserved. Subject to modification
U
= 20 V
i
I
= 60 mA
i
P
= 80 mW
i
Honeywell
7