Connecting cable
Terminal block
Cord clamp
Screw
Screw
Terminal cover
NOTE
• Use stranded wire only.
• Wire type : More than H07RN-F or 245 IEC66 (1.0 mm
How to Connect Remote Controller
for Wire Operation
CAUTION
• Be sure to install control wire along
the wall so that there is no slack and
fi x remote controller on the wall.
For indoor unit
1. Open the air inlet grille upward.
2. Securely remove two screws at the front panel.
3. Slightly open the lower part of the front panel then pull the upper part of
the front panel toward you to remove it from the rear plate as shown on
fi gure 1.
4. After removing the front panel, remove the Display unit and open the
cover as shown on fi gure 2 and 3.
5. Arrange the control wire as detail and specifi cation as shown on fi gure
4.
6. Securely connect the control wire to terminal of Display unit board as
shown on fi gure 5 (tighten fi rmly but not over 0.12 N·m (0.01 kgf·m)).
7. Set the control wire throughout at slot on front cover of Display unit then
reassembly Display with main casing by reverse process of fi gure 2 and
3. Make sure the control wire must not be pressed by front and rear
cover of Display unit.
8. Set the control wire out from indoor unit same portion as power supply
and connecting cable as shown on fi gure 6.
9. Reassembly the indoor unit by reverse process of 1 to 3.
Air inlet grille
Display unit
100 mm
Earth line
10 mm
10 mm
90 mm
Stripping length of the connecting cable
2
or more)
Indoor unit
Control wire
Remote controller
1
Front panel
2
3
Display board
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length less than 30 m.
Tighten fi rmly but
Terminal
not over 0.12 N·m
Control wire
(0.01 kgf·m)
For remote controller
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the polyester
sheet as shown on fi gure 7.
4. Insert control wire from rear side of remote controller as shown on
fi gure 8.
5. Fix control wire which arrange as shown on fi gure 9 and ! to terminal
by provided screws (tighten fi rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on fi gure ".
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on fi gure #.
8. Mark and arrange hole for fi x below screw (Ø3.1×25L) as shown on
fi gure #.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to fi x battery cover together with wall as
shown on fi gure $ (tighten fi rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
7
9
30 mm
10 mm
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length less than 30 m.
Control wire
Hole for hang
remote controller
Remote controller
Remote controller
"
5
4
70 mm
5 mm
Notch for wire out
5
Control wire
8
Polyester sheet
close hole for
insert control wire
Control wire
!
Tighten fi rmly but
not over 0.25 N·m
(0.03 kgf·m)
Control wire
Terminal
Control wire
Screw (Ø3.1×16L)
for hang remote
controller
Wall
Screw (Ø3.1×25L)
for fi x battery cover
#
6
EN
EN
ES
FR
IT
DE
PT
PL
CZ
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI