Service and maintenance

WARNING
Risk of injury, electric shock
Always disconnect the machine from the power
supply before performing any maintenance and
repair work.
All maintenance and repair work which requires
the machine housing to be opened should al-
ways be carried out by an authorised service
workshop.
Customer service and repair only
through manufacturer or service
workshops: Please find the nearest
address at: www.festool.com/service
EKAT
Only use original Festool spare parts!
4
Order No. at: www.festool.com/service
5
3
2
1
Damaged safety devices and components must be
repaired or replaced in a recognised specialist
workshop, unless otherwise indicated in the oper-
ating manual.
– A dust test must be performed at least once a
year or after 3000 operating hours, whichever oc-
curs first, by the manufacturer or an instructed
person. This test may include checks to deter-
mine whether the filter is damaged, the machine
is sealed properly and the monitoring features
are functioning correctly.
– During maintenance and repair work, all compo-
nents that cannot be cleaned satisfactorily must
be replaced. The old components must be sealed
in impermeable plastic bags prior to disposal in
compliance with applicable regulations for this
type of waste.
– Provided maintenance personnel or other per-
sons in the vicinity are not endangered, the user
must dismantle and clean the machine prior to
performing maintenance work. Appropriate pre-
cautionary measures include decontaminating
the machine prior to disassembly, making provi-
sions for locally filtered forced ventilation at the
location of machine disassembly, cleaning the
maintenance area and appropriate personal pro-
tective equipment.
26
10.1

Empty dirt trap [3], replace disposal bag

WARNING
Dust may arise when emptying the dirt trap
Wear a dust mask!
Open housing door [3-2].
Pull handle [3-1] forward.
The filter container is raised.
Remove dirt trap [3-3] completely.
Empty dirt trap or close disposal bag carefully
so that dust cannot escape and replace with a
new one.
 Always move the dirt trap back to the front and
push back the handle, otherwise the machine
will not function.
 Reset dirt trap emptying time, see chapter 8.5
or reset warning W9 with: 2x
.
10.2

Replace filter and sensor filter [4]

WARNING
Dust may arise when emptying the dirt trap
Wear a dust mask!
Open housing door [4-3].
Slacken screws [4-1] and remove housing part
[4-2].
Remove vacuum sensor hose [4-6]; press blue
ring on compression fitting and pull hose.
Slacken star-grip screw [4-5] and remove com-
pletely.
Remove supply air pipe [4-7].
Pull handle [4-4] forward and remove.
The handle is raised.
Remove filter container [4-8] with dirt trap.
Carefully tap filter into its mounting, put the bag
of the spare filter over the filter flange and in-
sert the filter into the bag during removal. Exer-
cise care when sealing the bag so that no dust
escapes. Observe the regional regulations on
filter disposal.
Carefully remove dust deposits around the filter
mounting using a damp cloth or a suitable mo-
bile dust extractor.
Insert new filter cartridge.
For ATEX turbine secure the ring cable lug of
the discharge lines as in the prior state.