Changing The Cooling Air Filter; Empty Condensate Container; Replace Electrical Fuses; Check Seals - Festool TURBO II M - 8 WP R1 Manual De Instrucciones

Turbina de aspiración
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
Unscrew central sensor air filter; reach in
through a main filter opening.
Clean compression fitting.
Insert new sensor air filter and tighten by hand.
 Always move filter and dirt trap back to the front
and push back handle, and screw in star-grip
screw, [4-5] otherwise the machine will not
function.
10.3

Changing the cooling air filter

There are cooling air filters at two locations on the
exhaust turbine, which must be replaced if re-
quired:
in the control cabinet:
DANGER
Injuries, electric shock or fire
Make sure that there is no residual voltage be-
fore commencing work in the control cabinet. All
of the frequency inverter's capacitors must be
fully discharged (wait for 10 minutes).
Ensure proper grounding!
Open control cabinet.
Slacken screws at the bracket of the cooling air
filter[5-1].
Remove filter and replace with a new one.
Under the upper cover:
Switch off device.
Remove upper cover after slackening screw
connections.
Slacken screws at the bracket of the cooling air
filter [5-2].
Remove filter and replace with a new one.
10.4

Empty condensate container

CAUTION
Non-emptying of condensate container
Material damage, condensate can get into the in-
side of the control box
Empty condensate container regularly.
Open housing door [6-1].
Place container under the supply unit.
Slacken screw at condensate container [6-2].
When the condensate is drained completely, re-
tighten the screws.
10.5

Replace electrical fuses

Annually: Have all fuses replaced by a qualified
electrician according to the circuit diagram.
In the event of a failure: Only by trained electrical
technician.
– On the top hat rail in the control cabinet, see Fig.
[7A].
– On the control system, see Fig. [7B].
10.6

Check seals

When emptying every tank: Check container seal
for damage and replace if necessary.
10.7

Check hoses and hose clips

Check hoses under the front cover for damage and
replace if necessary.
Check hose clips for tightness (tightening torque
4±0.2 Nm)
11

Accessories

WARNING
Risk of explosion resulting from the use of unap-
proved accessories and spare parts
For mobile dust extractors of design type 22 only
accessories and spare parts approved by Festool
especially for this purpose can be used - see
listed consumables, accessories list and spare
parts catalogue.
The order numbers for the accessories and filters
can be found in the Festool catalogue or on the In-
ternet at "www.festool.com".
12

Environment

Do not dispose of the device in house-
hold waste! Recycle devices, accesso-
ries and packaging. Observe applica-
ble national regulations.
EU only: In accordance with European
Directive on waste electrical and electronic equip-
ment and implementation in national law, used
electric power tools must be collected separately
and handed in for environmentally friendly recy-
cling.
Information on REACh: www.festool.com/reach
13

EU Declaration of Conformity

Exhaust turbines
Turbo II M- 8 WP R1
Turbo II M - 8 WP R1 ATEX
Turbo II M
GB
Serial no.
10016265
10016266
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Turbo ii m - 8 wp r1 atexTurbo ii m - 14 wp r1Turbo ii m - 14 wp r1 atex

Tabla de contenido