Use the following connecting cables:
Primary side (230 VAC)
Use only suitable installation cables in compliance with VDE (e.g. NYM 3×1.5 mm²).
Secondary side (7 VDC/ 12 VDC)
Use only original connection cable (FAR Order No. 2030043814).
Only for 7 V:
The resistance over the entire length of the cable (from the power supply to the
fitting) must be less than 3.4 ohms.
The cross-section must be selected according to the cable length.
13.4 Install one moisture-proof junction box per fitting (a).
13.5 Run an empty conduit (c; Ø 10 mm) from the moisture-proof junction box to the
flush-mounting cabinet.
13.6 Lay a 2-wire cable (b) in the empty conduit and slide it from the moisture-proof
junction box to the moisture-proof junction box.
13.7 Slide the connecting cable (d) for the sensor through the empty conduit (c).
☞
The plug must be easily accessible for the fitting.
13.8 Connect the connecting cable (d) in the moisture-proof junction box.
13.9 Close the moisture-proof junction box with the protective cap (e).
13.10 Connect the extension cable to the fitting.
14. Short Circuit and Overload Behaviour
In the event of a short circuit during network operation, the output remains
disconnected. After a short circuit, the voltage thresholds specified for activation and
deactivation apply only after power has been deactivated on the primary side or after
the voltage threshold of 7 V has been reached.
15. Fuses
Caution!
The power supply is secured with a 1.6 AT/250 V fuse on the primary side. When
this fuse triggers, it is very probable that the device is defective.
- 8 -